1.. zephyr:code-sample:: veea_x_3 2 :name: VEAA-X-3 proportional pressure control valve 3 :relevant-api: sensor_interface 4 5 Control a VEAA-X-3 proportional pressure control valve. 6 7Overview 8******** 9 10A sensor sample that demonstrates how to use a VEAA-X-3 device. 11 12Building and Running 13******************** 14 15This sample sets the valve setpoint then reads the actual pressure. 16This is done continuously. When the maximum supported pressure is reached the setpoint is reset to 17the valve's minimum supported pressure value. 18 19.. zephyr-app-commands:: 20 :zephyr-app: samples/sensor/veaa_x_3 21 :board: <board to use> 22 :goals: build flash 23 :compact: 24 25Sample Output 26============= 27 28.. code-block:: console 29 30 Testing test_veaa_x_3 31 Valve range: 1 to 200 kPa 32 Setpoint: 1 kPa, actual: 1 kPa 33 Setpoint: 2 kPa, actual: 2 kPa 34 Setpoint: 3 kPa, actual: 3 kPa 35 ... 36 Setpoint: 199 kPa, actual: 199 kPa 37 Setpoint: 200 kPa, actual: 200 kPa 38 Setpoint: 1 kPa, actual: 1 kPa 39 <repeats endlessly> 40