Lines Matching full:short
76 ShVddEN - Short to VDD enable
77 Enable or disable short to VDD functionality per channel.
109 wire and short-to-V DD diagnostics always use filtering and cannot be disabled
150 Set threshold voltage for short-to-V DD detection
151 0: Set threshold voltage for short-to-VDD detection to 9V (typ)
152 1: Set threshold voltage for short-to-VDD detection to 10V (typ)
153 2: Set threshold voltage for short-to-VDD detection to 12V (typ)
154 3: Set threshold voltage for short-to-VDD detection to 14V (typ)
165 Set the pullup current for open-wire and short-to-VDD detection
166 0: Set open-wire and short-to-VDD detection current to 60μA (typ)
167 1: Set open-wire and short-to-VDD detection current to 100μA (typ)
168 2: Set open-wire and short-to-VDD detection current to 300μA (typ)
169 3: Set open-wire and short-to-VDD detection current to 600μA (typ)