Lines Matching full:typ
113 1 - Minimum fault LED (FLED) on-time = 1s (typ)
114 2 - Minimum fault LED (FLED) on-time = 2s (typ)
115 3 - Minimum fault LED (FLED) on-time = 3s (typ)
125 false: To select regular blanking time (4ms, typ) for diagnostic fault bits, OWOff_
127 true: To select long blanking time (8ms, typ) for diagnostic fault bits, OWOff_
150 SYNCH watchdog timeout is 600ms (typ) if enabled.
162 0: Set threshold voltage for short-to-VDD detection to 9V (typ)
163 1: Set threshold voltage for short-to-VDD detection to 10V (typ)
164 2: Set threshold voltage for short-to-VDD detection to 12V (typ)
165 3: Set threshold voltage for short-to-VDD detection to 14V (typ)
177 0: Set open-wire and short-to-VDD detection current to 60μA (typ)
178 1: Set open-wire and short-to-VDD detection current to 100μA (typ)
179 2: Set open-wire and short-to-VDD detection current to 300μA (typ)
180 3: Set open-wire and short-to-VDD detection current to 600μA (typ)
193 1: Enable SPI Watchdog Status, set SPI and SYNCH Watchdog Timeout to 200ms (typ)
194 2: Enable SPI Watchdog Status, set SPI and SYNCH Watchdog Timeout to 600ms (typ)
195 3: Enable SPI Watchdog Status, set SPI and SYNCH Watchdog Timeout to 1.2s (typ)