Lines Matching full:short
87 ShVddEN - Short to VDD enable
88 Enable or disable short to VDD functionality per channel.
120 wire and short-to-V DD diagnostics always use filtering and cannot be disabled
161 Set threshold voltage for short-to-V DD detection
162 0: Set threshold voltage for short-to-VDD detection to 9V (typ)
163 1: Set threshold voltage for short-to-VDD detection to 10V (typ)
164 2: Set threshold voltage for short-to-VDD detection to 12V (typ)
165 3: Set threshold voltage for short-to-VDD detection to 14V (typ)
176 Set the pullup current for open-wire and short-to-VDD detection
177 0: Set open-wire and short-to-VDD detection current to 60μA (typ)
178 1: Set open-wire and short-to-VDD detection current to 100μA (typ)
179 2: Set open-wire and short-to-VDD detection current to 300μA (typ)
180 3: Set open-wire and short-to-VDD detection current to 600μA (typ)