1UniPhier UART controller 2 3Required properties: 4- compatible: should be "socionext,uniphier-uart". 5- reg: offset and length of the register set for the device. 6- interrupts: a single interrupt specifier. 7- clocks: phandle to the input clock. 8 9Optional properties: 10-auto-flow-control: enable automatic flow control support. 11 12Example: 13 aliases { 14 serial0 = &serial0; 15 }; 16 17 serial0: serial@54006800 { 18 compatible = "socionext,uniphier-uart"; 19 reg = <0x54006800 0x40>; 20 interrupts = <0 33 4>; 21 clocks = <&uart_clk>; 22 }; 23