1sysfs interface for analog devices adp8860 backlight driver 2----------------------------------------------------------- 3 4The backlight brightness control operates at three different levels for the 5adp8860, adp8861 and adp8863 devices: daylight (level 1), office (level 2) and 6dark (level 3). By default the brightness operates at the daylight brightness 7level. 8 9What: /sys/class/backlight/<backlight>/ambient_light_level 10Date: Apr, 2010 11KernelVersion: v2.6.35 12Contact: Michael Hennerich <michael.hennerich@analog.com> 13Description: 14 (RO) 13-bit conversion value for the first light sensor—high 15 byte (Bit 12 to Bit 8). The value is updated every 80 ms (when 16 the light sensor is enabled). 17 18 19What: /sys/class/backlight/<backlight>/ambient_light_zone 20Date: Apr, 2010 21KernelVersion: v2.6.35 22Contact: Michael Hennerich <michael.hennerich@analog.com> 23Description: 24 (RW) Read or write the specific level at which the backlight 25 operates. Value "0" enables automatic ambient light sensing, and 26 values "1", "2" or "3" set the control to daylight, office or 27 dark respectively. 28 29 30What: /sys/class/backlight/<backlight>/l1_daylight_max 31What: /sys/class/backlight/<backlight>/l2_office_max 32What: /sys/class/backlight/<backlight>/l3_dark_max 33Date: Apr, 2010 34KernelVersion: v2.6.35 35Contact: Michael Hennerich <michael.hennerich@analog.com> 36Description: 37 (RW) Maximum current setting for the backlight when brightness 38 is at one of the three levels (daylight, office or dark). This 39 is an input code between 0 and 127, which is transformed to a 40 value between 0 mA and 30 mA using linear or non-linear 41 algorithms. 42 43 44What: /sys/class/backlight/<backlight>/l1_daylight_dim 45What: /sys/class/backlight/<backlight>/l2_office_dim 46What: /sys/class/backlight/<backlight>/l3_dark_dim 47Date: Apr, 2010 48KernelVersion: v2.6.35 49Contact: Michael Hennerich <michael.hennerich@analog.com> 50Description: 51 (RW) Dim current setting for the backlight when brightness is at 52 one of the three levels (daylight, office or dark). This is an 53 input code between 0 and 127, which is transformed to a value 54 between 0 mA and 30 mA using linear or non-linear algorithms. 55