Home
last modified time | relevance | path

Searched refs:statusReg (Results 1 – 3 of 3) sorted by relevance

/hal_wurthelektronik-latest/sensors/WeSensorsSDK/WSEN_TIDS_2521020222501_hal/
DWSEN_TIDS_2521020222501_hal.c444 TIDS_status_t statusReg; in TIDS_isBusy() local
446 if (WE_FAIL == TIDS_ReadReg(sensorInterface, TIDS_STATUS_REG, 1, (uint8_t *) &statusReg)) in TIDS_isBusy()
451 *busy = (TIDS_state_t) statusReg.busy; in TIDS_isBusy()
464 TIDS_status_t statusReg; in TIDS_isUpperLimitExceeded() local
466 if (WE_FAIL == TIDS_ReadReg(sensorInterface, TIDS_STATUS_REG, 1, (uint8_t *) &statusReg)) in TIDS_isUpperLimitExceeded()
471 *state = (TIDS_state_t) statusReg.upperLimitExceeded; in TIDS_isUpperLimitExceeded()
484 TIDS_status_t statusReg; in TIDS_isLowerLimitExceeded() local
486 if (WE_FAIL == TIDS_ReadReg(sensorInterface, TIDS_STATUS_REG, 1, (uint8_t *) &statusReg)) in TIDS_isLowerLimitExceeded()
491 *state = (TIDS_state_t) statusReg.lowerLimitExceeded; in TIDS_isLowerLimitExceeded()
/hal_wurthelektronik-latest/sensors/WeSensorsSDK/WSEN_PADS_2511020213301_hal/
DWSEN_PADS_2511020213301_hal.c1633 PADS_status_t statusReg; in PADS_getTemperatureOverrunStatus() local
1635 if (WE_FAIL == PADS_ReadReg(sensorInterface, PADS_STATUS_REG, 1, (uint8_t *) &statusReg)) in PADS_getTemperatureOverrunStatus()
1640 *state = (PADS_state_t) statusReg.tempDataOverrun; in PADS_getTemperatureOverrunStatus()
1653 PADS_status_t statusReg; in PADS_getPressureOverrunStatus() local
1655 if (WE_FAIL == PADS_ReadReg(sensorInterface, PADS_STATUS_REG, 1, (uint8_t *) &statusReg)) in PADS_getPressureOverrunStatus()
1660 *state = (PADS_state_t) statusReg.presDataOverrun; in PADS_getPressureOverrunStatus()
1673 PADS_status_t statusReg; in PADS_isPressureDataAvailable() local
1675 if (WE_FAIL == PADS_ReadReg(sensorInterface, PADS_STATUS_REG, 1, (uint8_t *) &statusReg)) in PADS_isPressureDataAvailable()
1679 *state = (PADS_state_t) statusReg.presDataAvailable; in PADS_isPressureDataAvailable()
1692 PADS_status_t statusReg; in PADS_isTemperatureDataAvailable() local
[all …]
/hal_wurthelektronik-latest/sensors/WeSensorsSDK/WSEN_HIDS_2525020210001_hal/
DWSEN_HIDS_2525020210001_hal.c584 HIDS_status_t statusReg; in HIDS_isHumidityDataAvailable() local
586 if (WE_FAIL == HIDS_ReadReg(sensorInterface, HIDS_STATUS_REG, 1, (uint8_t *) &statusReg)) in HIDS_isHumidityDataAvailable()
591 *state = (HIDS_state_t) statusReg.humDataAvailable; in HIDS_isHumidityDataAvailable()
604 HIDS_status_t statusReg; in HIDS_isTemperatureDataAvailable() local
606 if (WE_FAIL == HIDS_ReadReg(sensorInterface, HIDS_STATUS_REG, 1, (uint8_t *) &statusReg)) in HIDS_isTemperatureDataAvailable()
611 *state = (HIDS_state_t) statusReg.tempDataAvailable; in HIDS_isTemperatureDataAvailable()
625 HIDS_status_t statusReg; in HIDS_isDataAvailable() local
627 if (WE_FAIL == HIDS_ReadReg(sensorInterface, HIDS_STATUS_REG, 1, (uint8_t *) &statusReg)) in HIDS_isDataAvailable()
634 *temp_state = (HIDS_state_t) statusReg.tempDataAvailable; in HIDS_isDataAvailable()
638 *hum_state = (HIDS_state_t) statusReg.humDataAvailable; in HIDS_isDataAvailable()