Home
last modified time | relevance | path

Searched refs:recv_op (Results 1 – 23 of 23) sorted by relevance

/hal_espressif-latest/components/bt/esp_ble_mesh/btc/
Dbtc_ble_mesh_lighting_model.c257 params.ctx.recv_op = ctx->recv_op; in bt_mesh_lighting_client_cb_evt_to_btc()
400 if (p_src_data->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_LIGHT_LC_PROPERTY_SET || in btc_ble_mesh_lighting_server_copy_req_data()
401 p_src_data->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_LIGHT_LC_PROPERTY_SET_UNACK) { in btc_ble_mesh_lighting_server_copy_req_data()
416 if (p_src_data->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_LIGHT_LC_PROPERTY_SET || in btc_ble_mesh_lighting_server_copy_req_data()
417 p_src_data->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_LIGHT_LC_PROPERTY_SET_UNACK) { in btc_ble_mesh_lighting_server_copy_req_data()
432 if (p_src_data->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_SENSOR_STATUS) { in btc_ble_mesh_lighting_server_copy_req_data()
464 if (arg->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_LIGHT_LC_PROPERTY_SET || in btc_ble_mesh_lighting_server_free_req_data()
465 arg->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_LIGHT_LC_PROPERTY_SET_UNACK) { in btc_ble_mesh_lighting_server_free_req_data()
470 if (arg->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_LIGHT_LC_PROPERTY_SET || in btc_ble_mesh_lighting_server_free_req_data()
471 arg->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_LIGHT_LC_PROPERTY_SET_UNACK) { in btc_ble_mesh_lighting_server_free_req_data()
[all …]
Dbtc_ble_mesh_sensor_model.c495 params.ctx.recv_op = ctx->recv_op; in bt_mesh_sensor_client_cb_evt_to_btc()
638 if (p_src_data->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_SENSOR_CADENCE_SET || in btc_ble_mesh_sensor_server_copy_req_data()
639 p_src_data->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_SENSOR_CADENCE_SET_UNACK) { in btc_ble_mesh_sensor_server_copy_req_data()
684 } else if (p_src_data->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_SENSOR_SETTING_SET || in btc_ble_mesh_sensor_server_copy_req_data()
685 p_src_data->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_SENSOR_SETTING_SET_UNACK) { in btc_ble_mesh_sensor_server_copy_req_data()
700 if (p_src_data->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_SENSOR_COLUMN_GET) { in btc_ble_mesh_sensor_server_copy_req_data()
712 } else if (p_src_data->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_SENSOR_SERIES_GET) { in btc_ble_mesh_sensor_server_copy_req_data()
727 if (p_src_data->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_SENSOR_CADENCE_SET || in btc_ble_mesh_sensor_server_copy_req_data()
728 p_src_data->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_SENSOR_CADENCE_SET_UNACK) { in btc_ble_mesh_sensor_server_copy_req_data()
740 } else if (p_src_data->ctx.recv_op == ESP_BLE_MESH_MODEL_OP_SENSOR_SETTING_SET || in btc_ble_mesh_sensor_server_copy_req_data()
[all …]
Dbtc_ble_mesh_generic_model.c413 params.ctx.recv_op = ctx->recv_op; in bt_mesh_generic_client_cb_evt_to_btc()
556 switch (p_src_data->ctx.recv_op) { in btc_ble_mesh_generic_server_copy_req_data()
590 switch (p_src_data->ctx.recv_op) { in btc_ble_mesh_generic_server_copy_req_data()
641 switch (arg->ctx.recv_op) { in btc_ble_mesh_generic_server_free_req_data()
655 switch (arg->ctx.recv_op) { in btc_ble_mesh_generic_server_free_req_data()
724 cb_params.ctx.recv_op = ctx->recv_op; in bt_mesh_generic_server_cb_evt_to_btc()
Dbtc_ble_mesh_time_scene_model.c259 params.ctx.recv_op = ctx->recv_op; in bt_mesh_time_scene_client_cb_evt_to_btc()
442 cb_params.ctx.recv_op = ctx->recv_op; in bt_mesh_time_scene_server_cb_evt_to_btc()
Dbtc_ble_mesh_config_model.c343 params.ctx.recv_op = ctx->recv_op; in bt_mesh_config_client_cb_evt_to_btc()
734 cb_params.ctx.recv_op = ctx->recv_op; in bt_mesh_config_server_cb_evt_to_btc()
Dbtc_ble_mesh_health_model.c276 params.ctx.recv_op = ctx->recv_op; in bt_mesh_health_client_cb_evt_to_btc()
Dbtc_ble_mesh_prov.c410 mesh_param.model_operation.opcode = ctx->recv_op; in btc_ble_mesh_server_model_op_cb()
436 mesh_param.client_recv_publish_msg.opcode = ctx->recv_op; in btc_ble_mesh_client_model_op_cb()
443 mesh_param.model_operation.opcode = ctx->recv_op; in btc_ble_mesh_client_model_op_cb()
/hal_espressif-latest/components/bt/esp_ble_mesh/mesh_models/client/
Dclient_common.c67 BT_DBG("Unexpected status message 0x%08x", ctx->recv_op); in bt_mesh_is_client_recv_publish_msg()
69 cli->publish_status(ctx->recv_op, model, ctx, buf); in bt_mesh_is_client_recv_publish_msg()
86 BT_DBG("Unexpected status message 0x%08x", ctx->recv_op); in bt_mesh_is_client_recv_publish_msg()
88 cli->publish_status(ctx->recv_op, model, ctx, buf); in bt_mesh_is_client_recv_publish_msg()
93 if (node->op_pending != ctx->recv_op) { in bt_mesh_is_client_recv_publish_msg()
94 BT_DBG("Unexpected status message 0x%08x", ctx->recv_op); in bt_mesh_is_client_recv_publish_msg()
96 cli->publish_status(ctx->recv_op, model, ctx, buf); in bt_mesh_is_client_recv_publish_msg()
102 BT_DBG("Unexpected status message 0x%08x", ctx->recv_op); in bt_mesh_is_client_recv_publish_msg()
104 cli->publish_status(ctx->recv_op, model, ctx, buf); in bt_mesh_is_client_recv_publish_msg()
Dtime_scene_client.c127 switch (ctx->recv_op) { in time_scene_status()
286 BT_ERR("Invalid Time Scene Status opcode 0x%04x", ctx->recv_op); in time_scene_status()
297 BT_DBG("Unexpected Time Scene Status 0x%04x", ctx->recv_op); in time_scene_status()
333 switch (ctx->recv_op) { in time_scene_status()
Dsensor_client.c111 switch (ctx->recv_op) { in sensor_status()
249 BT_ERR("Invalid Sensor Status opcode 0x%04x", ctx->recv_op); in sensor_status()
260 BT_DBG("Unexpected Sensor Status 0x%04x", ctx->recv_op); in sensor_status()
289 switch (ctx->recv_op) { in sensor_status()
Dgeneric_client.c173 switch (ctx->recv_op) { in generic_status()
521 BT_ERR("Invalid Generic Status opcode 0x%04x", ctx->recv_op); in generic_status()
532 BT_DBG("Unexpected Generic Status 0x%04x", ctx->recv_op); in generic_status()
584 switch (ctx->recv_op) { in generic_status()
Dlighting_client.c182 switch (ctx->recv_op) { in light_status()
636 BT_ERR("Invalid Lighting Status opcode 0x%04x", ctx->recv_op); in light_status()
647 BT_DBG("Unexpected Lighting Status 0x%04x", ctx->recv_op); in light_status()
710 switch (ctx->recv_op) { in light_status()
/hal_espressif-latest/components/bt/esp_ble_mesh/mesh_models/server/
Dgeneric_server.c167 if (ctx->recv_op == BLE_MESH_MODEL_OP_GEN_ONOFF_SET) { in gen_onoff_set()
191 if (ctx->recv_op == BLE_MESH_MODEL_OP_GEN_ONOFF_SET) { in gen_onoff_set()
211 if (ctx->recv_op == BLE_MESH_MODEL_OP_GEN_ONOFF_SET) { in gen_onoff_set()
345 if (ctx->recv_op == BLE_MESH_MODEL_OP_GEN_LEVEL_SET) { in gen_level_set()
373 if (ctx->recv_op == BLE_MESH_MODEL_OP_GEN_LEVEL_SET) { in gen_level_set()
393 if (ctx->recv_op == BLE_MESH_MODEL_OP_GEN_LEVEL_SET) { in gen_level_set()
453 if (ctx->recv_op == BLE_MESH_MODEL_OP_GEN_DELTA_SET) { in gen_delta_set()
494 if (ctx->recv_op == BLE_MESH_MODEL_OP_GEN_DELTA_SET) { in gen_delta_set()
514 if (ctx->recv_op == BLE_MESH_MODEL_OP_GEN_DELTA_SET) { in gen_delta_set()
563 if (ctx->recv_op == BLE_MESH_MODEL_OP_GEN_MOVE_SET) { in gen_move_set()
[all …]
Dlighting_server.c162 switch (ctx->recv_op) { in light_lightness_get()
179 BT_WARN("Unknown Light Lightness Get opcode 0x%04x", ctx->recv_op); in light_lightness_get()
257 if (ctx->recv_op == BLE_MESH_MODEL_OP_LIGHT_LIGHTNESS_SET) { in light_lightness_set()
292 if (ctx->recv_op == BLE_MESH_MODEL_OP_LIGHT_LIGHTNESS_SET) { in light_lightness_set()
321 if (ctx->recv_op == BLE_MESH_MODEL_OP_LIGHT_LIGHTNESS_SET) { in light_lightness_set()
369 if (ctx->recv_op == BLE_MESH_MODEL_OP_LIGHT_LIGHTNESS_LINEAR_SET) { in light_lightness_linear_set()
397 if (ctx->recv_op == BLE_MESH_MODEL_OP_LIGHT_LIGHTNESS_LINEAR_SET) { in light_lightness_linear_set()
417 if (ctx->recv_op == BLE_MESH_MODEL_OP_LIGHT_LIGHTNESS_LINEAR_SET) { in light_lightness_linear_set()
462 if (ctx->recv_op == BLE_MESH_MODEL_OP_LIGHT_LIGHTNESS_DEFAULT_SET) { in light_lightness_default_set()
539 if (ctx->recv_op == BLE_MESH_MODEL_OP_LIGHT_LIGHTNESS_RANGE_SET) { in light_lightness_range_set()
[all …]
Dtime_scene_server.c193 if (ctx->recv_op != BLE_MESH_MODEL_OP_TIME_STATUS) { in time_get()
200 switch (ctx->recv_op) { in time_get()
295 BT_WARN("Unknown Time Get opcode 0x%04x", ctx->recv_op); in time_get()
317 switch (ctx->recv_op) { in time_set()
396 BT_ERR("Unknown Time Set opcode 0x%04x", ctx->recv_op); in time_set()
400 switch (ctx->recv_op) { in time_set()
460 if (ctx->recv_op == BLE_MESH_MODEL_OP_SCENE_GET) { in send_scene_status()
560 switch (ctx->recv_op) { in scene_get()
573 BT_WARN("Unknown Scene Get opcode 0x%04x", ctx->recv_op); in scene_get()
641 if (ctx->recv_op == BLE_MESH_MODEL_OP_SCENE_RECALL) { in scene_recall()
[all …]
Dsensor_server.c409 if (ctx->recv_op != BLE_MESH_MODEL_OP_SENSOR_SETTING_SET || in send_sensor_setting_status()
588 switch (ctx->recv_op) { in sensor_get()
598 if (ctx->recv_op == BLE_MESH_MODEL_OP_SENSOR_DESCRIPTOR_GET || in sensor_get()
599 ctx->recv_op == BLE_MESH_MODEL_OP_SENSOR_GET) { in sensor_get()
608 if (ctx->recv_op == BLE_MESH_MODEL_OP_SENSOR_DESCRIPTOR_GET) { in sensor_get()
637 if (ctx->recv_op == BLE_MESH_MODEL_OP_SENSOR_COLUMN_GET) { in sensor_get()
671 if (ctx->recv_op == BLE_MESH_MODEL_OP_SENSOR_CADENCE_GET || in sensor_get()
672 ctx->recv_op == BLE_MESH_MODEL_OP_SENSOR_SETTINGS_GET) { in sensor_get()
678 if (ctx->recv_op == BLE_MESH_MODEL_OP_SENSOR_CADENCE_GET) { in sensor_get()
725 BT_WARN("Unknown Sensor Get opcode 0x%04x", ctx->recv_op); in sensor_get()
[all …]
Dstate_transition.c321 switch (ctx->recv_op) { in generic_level_work_handler()
356 switch (ctx->recv_op) { in generic_level_work_handler()
/hal_espressif-latest/components/bt/esp_ble_mesh/mesh_core/
Dhealth_srv.c106 if (ctx->recv_op != OP_HEALTH_FAULT_CLEAR) { in health_send_fault_status()
172 if (ctx->recv_op == OP_HEALTH_FAULT_CLEAR) { in health_fault_clear()
212 if (ctx->recv_op == OP_HEALTH_FAULT_TEST) { in health_fault_test()
270 if (ctx->recv_op == OP_ATTENTION_SET) { in attention_set()
322 if (ctx->recv_op == OP_HEALTH_PERIOD_SET) { in health_period_set()
Dhealth_cli.c108 BT_DBG("Unexpected Health Status 0x%04x", ctx->recv_op); in health_client_recv_status()
136 switch (ctx->recv_op) { in health_client_recv_status()
Dcfg_cli.c150 BT_DBG("Unexpected Config Status 0x%04x", ctx->recv_op); in cfg_client_recv_status()
218 switch (ctx->recv_op) { in cfg_client_recv_status()
504 if (ctx->recv_op == OP_MOD_SUB_LIST_VND) { in mod_sub_list()
592 if (ctx->recv_op == OP_VND_MOD_APP_LIST) { in mod_app_list()
Daccess.c701 rx->ctx.recv_op = opcode; in bt_mesh_model_recv()
/hal_espressif-latest/components/bt/esp_ble_mesh/mesh_core/include/
Dmesh_access.h161 uint32_t recv_op; member
/hal_espressif-latest/components/bt/esp_ble_mesh/api/
Desp_ble_mesh_defs.h546 uint32_t recv_op; member