Lines Matching +full:tri +full:- +full:default

4 # SPDX-License-Identifier: Apache-2.0
11 default 1
18 default 16
26 default 1
38 default "NONE"
43 channel with default SCBK. Once as secure channel is active with the
44 default key, the CP can send a KEYSET command to set new keys to the PD.
54 default 0x001A2B3C
61 default 1
68 default 1
75 default 0xCAFEBABE
78 A 4-byte serial number for the PD.
82 default 0x00010100
86 - Bit 0-7 : build version number;
87 - Bit 8-15 : minor version number;
88 - Bit 16-23: major version number;
98 default 0
102 - 01: PD monitors and reports the state of the circuit without any
103 supervision. The PD encodes the circuit status per its default
105 - 02: Like 01, plus: The PD accepts configuration of the encoding of the
108 - 03: Like 02, plus: PD supports supervised monitoring. The operating mode
110 - 04: Like 03, plus: the PD supports custom End-Of-Line settings within
115 default 0
125 default 0
129 - 01: The PD is able to activate and deactivate the Output per direct
131 - 02: Like 01, plus: The PD is able to accept configuration of the Output
136 de-energize the Output during the active state. This feature allows the
137 support of "fail-safe/fail-secure" operating modes.
138 - 03: Like 01, plus: The PD is able to accept timed commands to the
141 - 04: Like 02 and 03 - normal/inverted drive and timed operation.
145 default 0
155 default 0
159 - 01: the PD support on/off control only
160 - 02: the PD supports timed commands
161 - 03: like 02, plus bi-color LEDs
162 - 04: like 02, plus tri-color LEDs
166 default 0
176 default 0
180 - 01: the PD support on/off control only
181 - 02: the PD supports timed commands
185 default 0
195 default 0
199 - 00: The PD has no text display support
200 - 01: The PD supports 1 row of 16 characters
201 - 02: the PD supports 2 rows of 16 characters
202 - 03: the PD supports 4 rows of 16 characters
203 - 04: TBD.
207 default 0
217 default 0
221 - 01: the PD sends card data to the CP as array of bits, not exceeding
223 - 02: the PD sends card data to the CP as array of BCD characters, not
225 - 03: the PD can send card data to the CP as array of bits, or as an
234 default 0
238 - 00: The PD does not support time/date functionality
239 - 01: The PD understands time/date settings per Command osdp_TDSET
240 - 02: The PD is able to locally update the time and date