Lines Matching +full:active +full:- +full:channel
4 # SPDX-License-Identifier: Apache-2.0
37 string "Secure Channel Base Key (SCBK)"
41 Channel Base Key. When this field is sent to "NONE", the PD is set to
43 channel with default SCBK. Once as secure channel is active with the
78 A 4-byte serial number for the PD.
86 - Bit 0-7 : build version number;
87 - Bit 8-15 : minor version number;
88 - Bit 16-23: major version number;
102 - 01: PD monitors and reports the state of the circuit without any
104 interpretation of contact state to active/inactive status.
105 - 02: Like 01, plus: The PD accepts configuration of the encoding of the
106 open/closed circuit status to the reported active/inactive status. (User
108 - 03: Like 02, plus: PD supports supervised monitoring. The operating mode
110 - 04: Like 03, plus: the PD supports custom End-Of-Line settings within
129 - 01: The PD is able to activate and deactivate the Output per direct
131 - 02: Like 01, plus: The PD is able to accept configuration of the Output
136 de-energize the Output during the active state. This feature allows the
137 support of "fail-safe/fail-secure" operating modes.
138 - 03: Like 01, plus: The PD is able to accept timed commands to the
141 - 04: Like 02 and 03 - normal/inverted drive and timed operation.
159 - 01: the PD support on/off control only
160 - 02: the PD supports timed commands
161 - 03: like 02, plus bi-color LEDs
162 - 04: like 02, plus tri-color LEDs
180 - 01: the PD support on/off control only
181 - 02: the PD supports timed commands
199 - 00: The PD has no text display support
200 - 01: The PD supports 1 row of 16 characters
201 - 02: the PD supports 2 rows of 16 characters
202 - 03: the PD supports 4 rows of 16 characters
203 - 04: TBD.
221 - 01: the PD sends card data to the CP as array of bits, not exceeding
223 - 02: the PD sends card data to the CP as array of BCD characters, not
225 - 03: the PD can send card data to the CP as array of bits, or as an
238 - 00: The PD does not support time/date functionality
239 - 01: The PD understands time/date settings per Command osdp_TDSET
240 - 02: The PD is able to locally update the time and date