Lines Matching +full:positive +full:- +full:port +full:- +full:input
1 .. zephyr:code-sample:: mcux_lpcmp
2 :name: NXP MCUX Low-power Analog Comparator (LPCMP)
3 :relevant-api: sensor_interface
5 Get analog comparator data from an NXP MCUX Low-power Analog Comparator (LPCMP).
10 This sample show how to use the NXP MCUX Low-power Analog Comparator (LPCMP) driver.
12 In this application, the negative input port of the LPCMP is set to 7 which
13 means the input voltage comes from the LPCMP internal DAC, the reference
18 The positive input port is set to 0, the user needs to check the reference
19 manual and board schematic to confirm which specific port is used and can
20 connect an external voltage to that port and change the input voltage to
28 Building and Running for NXP FRDM-MCXN947
31 LPCMP positive input port voltage by changing the voltage input to J2-17.
33 .. zephyr-app-commands::
34 :zephyr-app: samples/sensor/mcux_lpcmp
39 Building and Running for NXP FRDM-MCXN236
42 LPCMP positive input port voltage by changing the voltage input to J2-8.
44 .. zephyr-app-commands::
45 :zephyr-app: samples/sensor/mcux_lpcmp
50 Building and Running for NXP FRDM-MCXA156
53 LPCMP positive input port voltage by changing the voltage input to J2-9.
55 .. zephyr-app-commands::
56 :zephyr-app: samples/sensor/mcux_lpcmp