Lines Matching +full:stallguard2 +full:- +full:threshold
1 # SPDX-FileCopyrightText: Copyright (c) 2024 Carl Zeiss Meditec AG
2 # SPDX-License-Identifier: Apache-2.0
7 activate-stallguard2:
10 Enable StallGuard2 feature, if the driver supports it.
12 stallguard2-threshold:
16 This signed value controls StallGuard2 level for stall output and sets the
20 -64 to +63: A higher value makes StallGuard2 less sensitive and requires more torque
23 stallguard-threshold-velocity:
27 Threshold velocity for StallGuard2 to detect a stall event.
30 stallguard-velocity-check-interval-ms:
34 Stallguard should not be enabled during motor spin-up.
36 stallguard-threshold-velocity before enabling stallguard.