Lines Matching +full:current +full:- +full:reference +full:- +full:control
2 # SPDX-License-Identifier: Apache-2.0
8 include: [sensor-device.yaml, i2c-device.yaml]
11 sd-gpios:
12 type: phandle-array
18 intb-gpios:
19 type: phandle-array
28 Set to identify the sensor as FDC2114 or FDC2214 (4-channel version)
33 Set the Auto-Scan Mode.
36 "active-channel" (single channel mode).
38 true = Auto-Scan conversions as selected by "rr-sequence"
45 Reference frequency of the used clock source in KHz.
50 rr-sequence:
54 Auto-Scan Sequence Configuration.
59 power-on-reset. This setting only applies if autoscan=true
66 - 0
67 - 1
68 - 2
70 active-channel:
77 power-on-reset. This setting only applies if autoscan=false
85 - 0
86 - 1
87 - 2
88 - 3
102 - 1
103 - 4
104 - 5
105 - 7
107 sensor-activate-sel:
109 default: "low-power"
113 The sensor uses low-power activation mode by default after
114 power-on-reset.
116 full-current = the FDC will drive maximum
117 sensor current for a shorter sensor activation time.
119 low-power = the FDC uses the value programmed by "idrive" during
122 - "full-current"
123 - "low-power"
125 ref-clk-src:
129 Select Reference Frequency Source.
131 The sensor uses the internal clock by default after power-on-reset.
133 internal = Use Internal oscillator as reference frequency
134 external = Reference frequency is provided from CLKIN pin.
136 - "internal"
137 - "external"
139 current-drive:
143 Select Current Sensor Drive.
145 The sensor uses normal current drive by default after power-on-reset.
146 High current drive is not supported if autoscan=false and will default
149 normal = The FDC will drive all channels with normal sensor current
152 high = The FDC will drive channel 0 with current >1.5mA.
154 - "normal"
155 - "high"
157 output-gain:
161 Output gain control (FDC2112, FDC2114 only)
163 The default output gain is 0 after power-on-reset.
170 - 0
171 - 1
172 - 2
173 - 3
175 child-binding:
177 Settings for each channel 0-1 (FDC2112 and FDC2212) or
178 0-3 (FDC2114 and FDC2214)
185 Channel X Reference Count Conversion Interval Time.
186 Valid range: 256 - 65535
193 The default offset value after power-on-reset is 0.
194 Valid range: 0 - 65535
204 Valid range: 0 - 65535
206 fref-divider:
210 Channel X Reference Divider.
212 Sets the divider for Channel X reference.
214 Valid range: 1 - 1023
220 Channel X Sensor drive current.
222 This field defines the Drive Current used during the settling +
224 Valid range: 0 - 31
226 fin-sel:
238 For single-ended sensor configuration:
242 - 1 # Divide by 1
243 - 2 # Divide by 2