Lines Matching +full:power +full:- +full:up
2 # SPDX-License-Identifier: Apache-2.0
9 #include <zephyr/dt-bindings/sensor/lis2dw12.h>
14 wakeup-duration = <LIS2DW12_DT_WAKEUP_4_ODR>;
15 ff-threshold = <LIS2DW12_DT_FF_THRESHOLD_500_mg>;
16 tap-mode = <LIS2DW12_DT_SINGLE_DOUBLE_TAP>;
17 power-mode = <LIS2DW12_DT_HP_MODE>;
18 bw-filt = <LIS2DW12_DT_FILTER_BW_ODR_DIV_2>;
21 include: sensor-device.yaml
24 irq-gpios:
25 type: phandle-array
33 int-pin:
47 configuration at power-up.
53 Range in g. Default is power-up configuration.
67 numbers are converted into their integer parts (1.65Hz -> 1, 12.5Hz -> 12).
69 power off state.
73 bw-filt:
77 Digital filtering cutoff bandwidth. Default is power-up configuration.
79 - 0 # LIS2DW12_DT_FILTER_BW_ODR_DIV_2
80 - 1 # LIS2DW12_DT_FILTER_BW_ODR_DIV_4
81 - 2 # LIS2DW12_DT_FILTER_BW_ODR_DIV_10
82 - 3 # LIS2DW12_DT_FILTER_BW_ODR_DIV_20
86 power-mode:
90 Specify the sensor power mode. Default is power-up configuration.
92 - 0 # LIS2DW12_DT_LP_M1
93 - 1 # LIS2DW12_DT_LP_M2
94 - 2 # LIS2DW12_DT_LP_M3
95 - 3 # LIS2DW12_DT_LP_M4
96 - 4 # LIS2DW12_DT_HP_MODE
100 # tap and tap-tap configuration section
101 # All default values are selected to match the power-up values.
102 # tap and tap-tap events can be generated on INT1 only.
104 tap-mode:
108 Tap mode. Default is power-up configuration.
110 - 0 # LIS2DW12_DT_SINGLE_TAP
111 - 1 # LIS2DW12_DT_SINGLE_DOUBLE_TAP
115 tap-threshold:
119 Tap X/Y/Z axes threshold. Default is power-up configuration.
122 Thresholds to start the tap-event detection procedure on the X/Y/Z axes.
123 Threshold values for each axis are unsigned 5-bit corresponding
124 to a 2g acceleration full-scale range. A threshold value equal to zero
130 tap-threshold = <12>, <0>, <14>
134 tap-shock:
138 Tap shock value. Default is power-up configuration.
140 This register represents the maximum time of an over-threshold signal
144 tap-latency:
148 Tap latency. Default is power-up configuration.
150 When double-tap recognition is enabled, this register expresses the
152 double-tap event. Where 0 equals 16*1/ODR and 1LSB = 32*1/ODR.
154 tap-quiet:
158 Expected quiet time after a tap detection. Default is power-up configuration.
164 low-noise:
171 hp-filter-path:
175 When enabled, the high-pass filter path is selected.
176 When disabled, the low-pass filter path is selected.
180 hp-ref-mode:
183 Enables the high-pass filter reference mode in the CTRL7 register.
184 When the high-pass filter is configured in reference mode,
192 drdy-pulsed:
195 Selects the pulsed mode for data-ready interrupt when enabled,
199 ff-duration:
210 100Hz ODR and 30ms ff-duration for recognize freefall detection
213 ff-threshold:
223 - 0 # LIS2DW12_DT_FF_THRESHOLD_156_mg
224 - 1 # LIS2DW12_DT_FF_THRESHOLD_219_mg
225 - 2 # LIS2DW12_DT_FF_THRESHOLD_250_mg
226 - 3 # LIS2DW12_DT_FF_THRESHOLD_312_mg
227 - 4 # LIS2DW12_DT_FF_THRESHOLD_344_mg
228 - 5 # LIS2DW12_DT_FF_THRESHOLD_406_mg
229 - 6 # LIS2DW12_DT_FF_THRESHOLD_469_mg
230 - 7 # LIS2DW12_DT_FF_THRESHOLD_500_mg
234 wakeup-duration:
244 - 0 # LIS2DW12_DT_WAKEUP_1_ODR
245 - 1 # LIS2DW12_DT_WAKEUP_2_ODR
246 - 2 # LIS2DW12_DT_WAKEUP_3_ODR
247 - 3 # LIS2DW12_DT_WAKEUP_4_ODR
251 sleep-duration:
255 The sleep duration. Default value is the register reset value (0000 -> 16*1/ODR).
263 - 0 # LIS2DW12_DT_SLEEP_0_ODR
265 - 15 # LIS2DW12_DT_SLEEP_15_ODR