Lines Matching +full:regulator +full:- +full:system +full:- +full:load

1 # Copyright 2019-2020, Peter Bigot Consulting, LLC
3 # SPDX-License-Identifier: Apache-2.0
9 linux/Documentation/devicetree/bindings/regulator/regulator.yaml.
14 regulator-name:
16 description: A string used as a descriptive name for regulator outputs
18 regulator-init-microvolt:
22 regulator-min-microvolt:
26 regulator-max-microvolt:
30 regulator-microvolt-offset:
34 regulator-init-microamp:
38 regulator-min-microamp:
42 regulator-max-microamp:
46 regulator-input-current-limit-microamp:
48 description: maximum input current regulator allows
50 regulator-always-on:
52 description: boolean, regulator should never be disabled
54 regulator-boot-on:
57 bootloader/firmware enabled regulator.
58 It's expected that this regulator was left on by the bootloader.
62 software cannot read the state of the regulator.
64 regulator-boot-off:
67 Regulator should be disabled on boot.
69 regulator-allow-bypass:
71 description: allow the regulator to go into bypass mode
73 regulator-allow-set-load:
75 description: allow the regulator performance level to be configured
77 regulator-ramp-delay:
80 ramp delay for regulator(in uV/us) For hardware which supports disabling
82 (regulator-ramp-delay = <0>) for disabling ramp delay.
84 regulator-enable-ramp-delay:
89 property describes the total system ramp time required due to the
90 combination of internal ramping of the regulator itself, and board design
91 issues such as trace capacitance and load on the supply.
93 regulator-settling-time-us:
96 Settling time, in microseconds, for voltage change if regulator have the
97 constant time for any level voltage change. This is useful when regulator
100 regulator-settling-time-up-us:
103 Settling time, in microseconds, for voltage increase if the regulator
107 regulator-settling-time-down-us:
110 Settling time, in microseconds, for voltage decrease if the regulator
114 regulator-soft-start:
118 regulator-initial-mode:
123 explains which values the regulator supports.
125 regulator-allowed-modes:
129 regulator at run-time. Elements may be specified in any order. The set of
131 each device binding document explains which values the regulator supports.
133 regulator-system-load:
136 Load in uA present on regulator that is not captured by any consumer
139 regulator-pull-down:
141 description: Enable pull down resistor when the regulator is disabled.
143 regulator-over-current-protection:
147 regulator-oc-protection-microamp:
155 regulator-oc-error-microamp:
163 regulator-oc-warn-microamp:
172 regulator-ov-protection-microvolt:
178 omitted. Limit is given as microvolt offset from voltage set to regulator.
180 regulator-ov-error-microvolt:
187 microvolt offset from voltage set to regulator.
189 regulator-ov-warn-microvolt:
197 voltage set to regulator.
199 regulator-uv-protection-microvolt:
206 regulator.
208 regulator-uv-error-microvolt:
215 microvolt offset from voltage set to regulator.
217 regulator-uv-warn-microvolt:
225 voltage set to regulator.
227 regulator-temp-protection-kelvin:
235 regulator-temp-error-kelvin:
243 regulator-temp-warn-kelvin:
252 regulator-active-discharge:
255 - 0
256 - 1
263 regulator-max-step-microvolt:
269 startup-delay-us:
273 off-on-delay-us: