Lines Matching +full:regulator +full:- +full:initial +full:- +full:mode
1 # Copyright 2019-2020, Peter Bigot Consulting, LLC
3 # SPDX-License-Identifier: Apache-2.0
9 linux/Documentation/devicetree/bindings/regulator/regulator.yaml.
14 regulator-name:
16 description: A string used as a descriptive name for regulator outputs
18 regulator-init-microvolt:
22 regulator-min-microvolt:
26 regulator-max-microvolt:
30 regulator-microvolt-offset:
34 regulator-init-microamp:
38 regulator-min-microamp:
42 regulator-max-microamp:
46 regulator-input-current-limit-microamp:
48 description: maximum input current regulator allows
50 regulator-always-on:
52 description: boolean, regulator should never be disabled
54 regulator-boot-on:
57 bootloader/firmware enabled regulator.
58 It's expected that this regulator was left on by the bootloader.
62 software cannot read the state of the regulator.
64 regulator-boot-off:
67 Regulator should be disabled on boot.
69 regulator-allow-bypass:
71 description: allow the regulator to go into bypass mode
73 regulator-allow-set-load:
75 description: allow the regulator performance level to be configured
77 regulator-ramp-delay:
80 ramp delay for regulator(in uV/us) For hardware which supports disabling
82 (regulator-ramp-delay = <0>) for disabling ramp delay.
84 regulator-enable-ramp-delay:
90 combination of internal ramping of the regulator itself, and board design
93 regulator-settling-time-us:
96 Settling time, in microseconds, for voltage change if regulator have the
97 constant time for any level voltage change. This is useful when regulator
100 regulator-settling-time-up-us:
103 Settling time, in microseconds, for voltage increase if the regulator
107 regulator-settling-time-down-us:
110 Settling time, in microseconds, for voltage decrease if the regulator
114 regulator-soft-start:
118 regulator-initial-mode:
121 Initial operating mode. The set of possible operating modes depends on the
123 explains which values the regulator supports.
125 regulator-allowed-modes:
129 regulator at run-time. Elements may be specified in any order. The set of
131 each device binding document explains which values the regulator supports.
133 regulator-system-load:
136 Load in uA present on regulator that is not captured by any consumer
139 regulator-pull-down:
141 description: Enable pull down resistor when the regulator is disabled.
143 regulator-over-current-protection:
147 regulator-oc-protection-microamp:
155 regulator-oc-error-microamp:
163 regulator-oc-warn-microamp:
172 regulator-ov-protection-microvolt:
178 omitted. Limit is given as microvolt offset from voltage set to regulator.
180 regulator-ov-error-microvolt:
187 microvolt offset from voltage set to regulator.
189 regulator-ov-warn-microvolt:
197 voltage set to regulator.
199 regulator-uv-protection-microvolt:
206 regulator.
208 regulator-uv-error-microvolt:
215 microvolt offset from voltage set to regulator.
217 regulator-uv-warn-microvolt:
225 voltage set to regulator.
227 regulator-temp-protection-kelvin:
235 regulator-temp-error-kelvin:
243 regulator-temp-warn-kelvin:
252 regulator-active-discharge:
255 - 0
256 - 1
263 regulator-max-step-microvolt:
269 startup-delay-us:
273 off-on-delay-us: