52 description: boolean, regulator should never be disabled
61 This property is intended to only be used for regulators where
67 Regulator should be disabled on boot.
75 description: allow the regulator performance level to be configured
81 ramp rate, it should be explicitly initialised to zero
129 regulator at run-time. Elements may be specified in any order. The set of
151 emergency shutdown. Zero can be passed to disable protection and value '1'
152 indicates that protection should be enabled but limit setting can be
159 probably is malfunctional and damage prevention is requested. Zero can be
161 should be enabled but limit setting can be omitted.
167 still to be functional but approaching limit where it gets damaged.
168 Recovery actions should be initiated. Zero can be passed to disable
169 detection and value '1' indicates that detection should be enabled but
170 limit setting can be omitted.
176 emergency shutdown. Zero can be passed to disable protection and value '1'
177 indicates that protection should be enabled but limit setting can be
184 probably is malfunctional and damage prevention is requested Zero can be
186 should be enabled but limit setting can be omitted. Limit is given as
193 still to be functional but approaching limit where it gets damaged.
194 Recovery actions should be initiated. Zero can be passed to disable
195 detection and value '1' indicates that detection should be enabled but
196 limit setting can be omitted. Limit is given as microvolt offset from
203 performs emergency shutdown. Zero can be passed to disable protection and
204 value '1' indicates that protection should be enabled but limit setting
205 can be omitted. Limit is given as microvolt offset from voltage set to
212 probably is malfunctional and damage prevention is requested Zero can be
214 should be enabled but limit setting can be omitted. Limit is given as
221 assumed still to be functional but approaching limit where it gets
222 damaged. Recovery actions should be initiated. Zero can be passed to
223 disable detection and value '1' indicates that detection should be enabled
224 but limit setting can be omitted. Limit is given as microvolt offset from
231 performs emergency shutdown. Zero can be passed to disable protection and
232 value '1' indicates that protection should be enabled but limit setting
233 can be omitted.
240 can be passed to disable error detection and value '1' indicates that
241 detection should be enabled but limit setting can be omitted.
247 assumed still to be functional but approaching limit where it gets
248 damaged. Recovery actions should be initiated. Zero can be passed to
249 disable detection and value '1' indicates that detection should be enabled
250 but limit setting can be omitted.
266 Maximum difference between current and target voltages that can be changed