*** Variables *** ${PLATFROM} platforms/cpus/stm32f4.repl ${BIN} https://dl.antmicro.com/projects/renode/nucleo_f401re--zephyr-dht_polling.elf-s_651648-b107cceed1ebc23c894d983a6e519a6e494aee88 ${UART} sysbus.usart2 ${SENSOR} sysbus.i2c1.hs3001 ${CSV2RESD} ${RENODETOOLS}/csv2resd/csv2resd.py ${SAMPLES_CSV} ${CURDIR}/HS3001-samples.csv *** Keywords *** Create Machine Execute Command mach create Execute Command machine LoadPlatformDescription @${PLATFROM} Execute Command machine LoadPlatformDescriptionFromString "hs3001: Sensors.HS3001 @ i2c1 0x44" Execute Command sysbus LoadELF @${BIN} Create Terminal Tester ${UART} Set Enviroment [Arguments] ${temperature}=0.00 ${humidity}=0.00 Execute Command ${SENSOR} Temperature ${temperature} Execute Command ${SENSOR} Humidity ${humidity} Check Enviroment [Arguments] ${temperature}=0.00 ${humidity}=0.00 # The '\xc2\xb0' escape sequence is the unicode character: '°' Wait For Line On Uart temp is ${temperature} \xc2\xb0C humidity is ${humidity} %RH Create RESD File [Arguments] ${path} ${resd_path}= Allocate Temporary File ${args}= Catenate SEPARATOR=, ... "--input", r"${path}" ... "--map", "temperature:temp::0" ... "--map", "humidity:humidity::0" ... "--start-time", "0" ... "--frequency", "1" ... r"${resd_path}" Evaluate subprocess.run([sys.executable, "${CSV2RESD}", ${args}]) sys,subprocess RETURN ${resd_path} *** Test Cases *** Should Read Temperature And Humidity Create Machine # Due the finite precision of the sensor we don't allways expect the exact same # values as the ones that where set Check Enviroment temperature=0.00 humidity=0.00 Set Enviroment temperature=25.00 Check Enviroment temperature=25.01 Set Enviroment humidity=50.00 Check Enviroment humidity=50.10 Set Enviroment temperature=12.32 humidity=33.71 Check Enviroment temperature=12.33 humidity=33.71 Set Enviroment temperature=-16.67 humidity=92.01 Check Enviroment temperature=-16.-66 humidity=92.04 Set Enviroment temperature=88.02 humidity=8.50 Check Enviroment temperature=88.08 humidity=8.50 Should Read Samples From RESD Create Machine ${resd_path}= Create RESD File ${SAMPLES_CSV} # Explicitly set temperature and humidity before loading RESD. # Sensor will default to these values after RESD stream ends. Set Enviroment temperature=25.56 humidity=30.39 Execute Command ${SENSOR} FeedTemperatureSamplesFromRESD @${resd_path} Execute Command ${SENSOR} FeedHumiditySamplesFromRESD @${resd_path} Check Enviroment temperature=-9.-99 humidity=0.00 Check Enviroment temperature=0.00 humidity=20.00 Check Enviroment temperature=4.99 humidity=40.05 Check Enviroment temperature=10.00 humidity=60.01 Check Enviroment temperature=15.00 humidity=80.31 # Sensor should go back to the default values after the RESD file finishes Check Enviroment temperature=25.56 humidity=30.39 Check Enviroment temperature=25.56 humidity=30.39