Home
last modified time | relevance | path

Searched refs:ht_opmode (Results 1 – 12 of 12) sorted by relevance

/Linux-v6.6/net/mac80211/
Dmesh_plink.c161 u16 ht_opmode; in mesh_set_ht_prot_mode() local
195 ht_opmode = IEEE80211_HT_OP_MODE_PROTECTION_NONHT_MIXED; in mesh_set_ht_prot_mode()
198 ht_opmode = IEEE80211_HT_OP_MODE_PROTECTION_20MHZ; in mesh_set_ht_prot_mode()
200 ht_opmode = IEEE80211_HT_OP_MODE_PROTECTION_NONE; in mesh_set_ht_prot_mode()
202 if (sdata->vif.bss_conf.ht_operation_mode == ht_opmode) in mesh_set_ht_prot_mode()
205 sdata->vif.bss_conf.ht_operation_mode = ht_opmode; in mesh_set_ht_prot_mode()
206 sdata->u.mesh.mshcfg.ht_opmode = ht_opmode; in mesh_set_ht_prot_mode()
207 mpl_dbg(sdata, "selected new HT protection mode %d\n", ht_opmode); in mesh_set_ht_prot_mode()
Ddebugfs_netdev.c675 IEEE80211_IF_FILE(ht_opmode, u.mesh.mshcfg.ht_opmode, DEC);
814 MESHPARAMS_ADD(ht_opmode); in add_mesh_config()
Dcfg.c2598 conf->ht_opmode = nconf->ht_opmode; in ieee80211_update_mesh_config()
2599 sdata->vif.bss_conf.ht_operation_mode = nconf->ht_opmode; in ieee80211_update_mesh_config()
2736 if (params->ht_opmode >= 0) { in ieee80211_change_bss()
2737 link->conf->ht_operation_mode = (u16)params->ht_opmode; in ieee80211_change_bss()
Dmesh.c1207 ifmsh->mshcfg.ht_opmode; in ieee80211_start_mesh()
Dmlme.c499 u16 ht_opmode; in ieee80211_config_bw() local
528 ht_opmode = le16_to_cpu(ht_oper->operation_mode); in ieee80211_config_bw()
529 if (link->conf->ht_operation_mode != ht_opmode) { in ieee80211_config_bw()
531 link->conf->ht_operation_mode = ht_opmode; in ieee80211_config_bw()
/Linux-v6.6/net/wireless/
Dmesh.c78 .ht_opmode = IEEE80211_HT_OP_MODE_PROTECTION_NONHT_MIXED,
Dtrace.h66 __field(u16, ht_opmode) \
104 __entry->ht_opmode = conf->ht_opmode; \
1143 __field(int, ht_opmode)
1152 __entry->ht_opmode = params->ht_opmode;
1159 __entry->ap_isolate, __entry->ht_opmode)
Dnl80211.c8007 params.ht_opmode = -1; in nl80211_set_bss()
8029 params.ht_opmode = in nl80211_set_bss()
8202 cur_params.ht_opmode) || in nl80211_get_mesh_config()
8302 u16 ht_opmode; in nl80211_parse_mesh_config() local
8400 ht_opmode = nla_get_u16(tb[NL80211_MESHCONF_HT_OPMODE]); in nl80211_parse_mesh_config()
8402 if (ht_opmode & ~(IEEE80211_HT_OP_MODE_PROTECTION | in nl80211_parse_mesh_config()
8408 ht_opmode &= ~IEEE80211_HT_OP_MODE_NON_HT_STA_PRSNT; in nl80211_parse_mesh_config()
8410 cfg->ht_opmode = ht_opmode; in nl80211_parse_mesh_config()
/Linux-v6.6/drivers/net/wireless/ralink/rt2x00/
Drt2x00config.c99 erp.ht_opmode = bss_conf->ht_operation_mode; in rt2x00lib_config_erp()
Drt2x00.h453 u16 ht_opmode; member
Drt2800lib.c2025 bool any_sta_nongf = !!(erp->ht_opmode & in rt2800_config_ht_opmode()
2027 u8 protection = erp->ht_opmode & IEEE80211_HT_OP_MODE_PROTECTION; in rt2800_config_ht_opmode()
/Linux-v6.6/include/net/
Dcfg80211.h2213 int ht_opmode; member
2323 u16 ht_opmode; member