Searched refs:PMBUS_VIRT_BASE (Results 1 – 6 of 6) sorted by relevance
79 if (reg >= PMBUS_VIRT_BASE) in max15301_read_word_data()115 if (reg >= PMBUS_VIRT_BASE) in max15301_write_word_data()
171 if (reg >= PMBUS_VIRT_BASE) in zl6100_read_word_data()263 if (reg >= PMBUS_VIRT_BASE) in zl6100_write_word_data()
118 if (reg >= PMBUS_VIRT_BASE) in bpa_rs600_read_word_data()
158 PMBUS_VIRT_BASE = 0x100, enumerator
278 if (reg >= PMBUS_VIRT_BASE) in _pmbus_write_word_data()392 if (reg >= PMBUS_VIRT_BASE) in _pmbus_read_word_data()
87 Virtual commands are named PMBUS_VIRT_xxx and start with PMBUS_VIRT_BASE. All157 if (command >= PMBUS_VIRT_BASE) /* For word commands/registers only */