Searched refs:related_cpus (Results 1 – 16 of 16) sorted by relevance
| /Linux-v5.4/drivers/thermal/ |
| D | cpu_cooling.c | 375 u32 ncpus = cpumask_weight(policy->related_cpus); in cpufreq_get_requested_power() 380 for_each_cpu(cpu, policy->related_cpus) { in cpufreq_get_requested_power() 400 trace_thermal_power_cpu_get_power(policy->related_cpus, freq, in cpufreq_get_requested_power() 477 trace_thermal_power_cpu_limit(policy->related_cpus, target_freq, *state, in cpufreq_power2state() 564 num_cpus = cpumask_weight(policy->related_cpus); in __cpufreq_cooling_register()
|
| /Linux-v5.4/drivers/acpi/ |
| D | processor_thermal.c | 132 for_each_cpu(cpu, policy->related_cpus) { in acpi_thermal_cpufreq_init() 152 for_each_cpu(cpu, policy->related_cpus) { in acpi_thermal_cpufreq_exit()
|
| D | processor_perflib.c | 164 for_each_cpu(cpu, policy->related_cpus) { in acpi_processor_ppc_init() 184 for_each_cpu(cpu, policy->related_cpus) { in acpi_processor_ppc_exit()
|
| /Linux-v5.4/drivers/base/ |
| D | arch_topology.c | 186 cpumask_pr_args(policy->related_cpus), in init_cpu_capacity_callback() 189 cpumask_andnot(cpus_to_visit, cpus_to_visit, policy->related_cpus); in init_cpu_capacity_callback() 191 for_each_cpu(cpu, policy->related_cpus) { in init_cpu_capacity_callback()
|
| /Linux-v5.4/drivers/cpufreq/ |
| D | scmi-cpufreq.c | 58 arch_set_freq_scale(policy->related_cpus, freq, in scmi_cpufreq_set_target() 71 arch_set_freq_scale(policy->related_cpus, target_freq, in scmi_cpufreq_fast_switch()
|
| D | cpufreq.c | 847 return cpufreq_show_cpus(policy->related_cpus, buf); in show_related_cpus() 905 cpufreq_freq_attr_ro(related_cpus); 919 &related_cpus.attr, 1186 if (!zalloc_cpumask_var(&policy->related_cpus, GFP_KERNEL)) in cpufreq_policy_alloc() 1244 free_cpumask_var(policy->related_cpus); in cpufreq_policy_alloc() 1262 for_each_cpu(cpu, policy->related_cpus) in cpufreq_policy_free() 1289 free_cpumask_var(policy->related_cpus); in cpufreq_policy_free() 1307 WARN_ON(!cpumask_test_cpu(cpu, policy->related_cpus)); in cpufreq_online() 1333 cpumask_copy(policy->cpus, policy->related_cpus); in cpufreq_online() 1353 cpumask_copy(policy->related_cpus, policy->cpus); in cpufreq_online() [all …]
|
| D | cpufreq-dt.c | 48 arch_set_freq_scale(policy->related_cpus, freq, in set_target() 318 dev_pm_opp_of_cpumask_remove_table(policy->related_cpus); in cpufreq_exit()
|
| D | qcom-cpufreq-hw.c | 42 arch_set_freq_scale(policy->related_cpus, freq, in qcom_cpufreq_hw_target_index() 79 arch_set_freq_scale(policy->related_cpus, freq, in qcom_cpufreq_hw_fast_switch()
|
| D | cpufreq_governor.c | 367 for_each_cpu(j, policy->related_cpus) { in alloc_policy_dbs_info() 382 for_each_cpu(j, policy_dbs->policy->related_cpus) { in free_policy_dbs_info()
|
| D | scpi-cpufreq.c | 65 arch_set_freq_scale(policy->related_cpus, freq, in scpi_cpufreq_set_target()
|
| D | arm_big_little.c | 236 arch_set_freq_scale(policy->related_cpus, freqs_new, in bL_cpufreq_set_target() 516 put_cluster_clk_and_freq_table(cpu_dev, policy->related_cpus); in bL_cpufreq_exit()
|
| /Linux-v5.4/Documentation/cpu-freq/ |
| D | pcc-cpufreq.txt | 41 2.4 related_cpus 192 2.4 related_cpus: 194 The related_cpus field is identical to affected_cpus. 197 related_cpus : 4
|
| /Linux-v5.4/kernel/sched/ |
| D | cpufreq_schedutil.c | 684 cpumask_first(policy->related_cpus)); in sugov_kthread_create() 698 kthread_bind_mask(thread, policy->related_cpus); in sugov_kthread_create()
|
| /Linux-v5.4/include/linux/ |
| D | cpufreq.h | 54 cpumask_var_t related_cpus; /* Online + Offline CPUs */ member
|
| /Linux-v5.4/Documentation/ABI/testing/ |
| D | sysfs-devices-system-cpu | 258 value of related_cpus may be different from freqdomain_cpus. This
|
| /Linux-v5.4/Documentation/admin-guide/pm/ |
| D | cpufreq.rst | 268 ``related_cpus``
|