Home
last modified time | relevance | path

Searched refs:diode (Results 1 – 25 of 49) sorted by relevance

12

/Linux-v5.10/Documentation/devicetree/bindings/rtc/
Ddallas,ds1390.txt11 - trickle-diode-disable : Do not use internal trickle charger diode
12 Should be given if internal trickle charger diode should be disabled
Dti,bq32k.txt11 - trickle-diode-disable : Do not use internal trickle charger diode
12 Should be given if internal trickle charger diode should be disabled
Depson,rx8900.txt12 - trickle-diode-disable : boolean, if present will disable internal trickle
13 charger diode
21 trickle-diode-disable;
Drtc-ds1307.txt40 - trickle-diode-disable : ds1339, ds1340 and ds1388 only
41 Do not use internal trickle charger diode
42 Should be given if internal trickle charger diode should be disabled
Dabracon,abx80x.txt29 - "abracon,tc-diode": should be "standard" (0.6V) or "schottky" (0.3V)
/Linux-v5.10/Documentation/hwmon/
Dmax6639.rst23 temperature and one external diode-connected transistor or two external
24 diode-connected transistors.
33 temp1_fault R Temperature channel 1 diode fault
34 temp2_fault R Temperature channel 2 diode fault
Dmax6697.rst75 remote temperature sensors. Remote temperature sensors are diode-connected
76 thermal transitors, except for MAX6698 which supports three diode-connected
90 tempX_fault RO temperature diode fault (remote sensors only)
Dmax31730.rst23 temperatures of three external diode-connected transistors. The operating
26 diode, while beta compensation corrects for temperature-measurement
Dsmsc47m192.rst85 temp1_input chip temperature measured by on-chip diode
87 would typically be wired to the diode inside the CPU)
105 temp[2-3]_input_fault diode fault flags for temperature inputs 2 and 3.
108 to ground or Vcc. '1' indicates a diode fault.
Dmax6642.rst24 well as the temperature on one external diode.
Dthmc50.rst45 external diode-type temperature sensor (compatible w/ the diode sensor inside
Dmax1619.rst24 well as the temperature of up to one external diode.
Dvt1211.rst68 Reading 1 temp1 Intel thermal diode
69 Reading 3 temp2 Internal thermal diode
126 internal thermal diode and the driver does all the scaling for temp2 and
131 Temp1 is an Intel-type thermal diode which requires the following formula to
Dw83781d.rst141 beta value in the sensor files. '1' is the PII/Celeron diode, '2' is the
197 - Problems with diode/thermistor settings (supported?)
260 > programmable to be either thermistor or Pentium II diode inputs.
261 > How do I program them for diode inputs? I can't find any register
262 > to program these to be diode inputs.
270 diode 1 1 1
276 PII thermal diode 1 1 1
277 2N3904 diode 0 0 0
Dlm83.rst31 a stripped down version of the LM83 that only supports one external diode.
34 in that the later can only sense the temperature of one external diode.
Demc2103.rst35 as temp3 and temp4. If only one diode is attached to this channel, temp4
Dltc2990.rst30 diode.
Dbt1-pvt.rst54 temp1: CPU embedded diode -48.38C - +147.438C
88 diode).
Dw83l785ts.rst23 temperature of a single external diode. The high limit is
Dlm95234.rst32 graphics processors or diode-connected 2N3904s. The chip's TruTherm
Dlm95245.rst29 the temperature of a remote diode as well as its own temperature.
/Linux-v5.10/drivers/iio/temperature/
Dltc2983.c566 struct ltc2983_diode *diode = to_diode(sensor); in ltc2983_diode_assign_chan() local
569 chan_val = LTC2983_DIODE_CFG(diode->sensor_config); in ltc2983_diode_assign_chan()
570 chan_val |= LTC2983_DIODE_EXC_CURRENT(diode->excitation_current); in ltc2983_diode_assign_chan()
571 chan_val |= LTC2983_DIODE_IDEAL_FACTOR(diode->ideal_factor_value); in ltc2983_diode_assign_chan()
1012 struct ltc2983_diode *diode; in ltc2983_diode_new() local
1016 diode = devm_kzalloc(&st->spi->dev, sizeof(*diode), GFP_KERNEL); in ltc2983_diode_new()
1017 if (!diode) in ltc2983_diode_new()
1021 diode->sensor_config = LTC2983_DIODE_SGL(1); in ltc2983_diode_new()
1024 diode->sensor_config |= LTC2983_DIODE_3_CONV_CYCLE(1); in ltc2983_diode_new()
1027 diode->sensor_config |= LTC2983_DIODE_AVERAGE_ON(1); in ltc2983_diode_new()
[all …]
/Linux-v5.10/drivers/rtc/
Drtc-abx80x.c561 const char *diode; in abx80x_dt_trickle_cfg() local
566 ret = of_property_read_string(np, "abracon,tc-diode", &diode); in abx80x_dt_trickle_cfg()
570 if (!strcmp(diode, "standard")) { in abx80x_dt_trickle_cfg()
572 } else if (!strcmp(diode, "schottky")) { in abx80x_dt_trickle_cfg()
575 dev_dbg(&client->dev, "Invalid tc-diode value: %s\n", diode); in abx80x_dt_trickle_cfg()
Drtc-ds1307.c522 static u8 do_trickle_setup_ds1339(struct ds1307 *ds1307, u32 ohms, bool diode) in do_trickle_setup_ds1339() argument
524 u8 setup = (diode) ? DS1307_TRICKLE_CHARGER_DIODE : in do_trickle_setup_ds1339()
547 static u8 do_trickle_setup_rx8130(struct ds1307 *ds1307, u32 ohms, bool diode) in do_trickle_setup_rx8130() argument
551 if (diode) in do_trickle_setup_rx8130()
1332 bool diode = chip->charge_default; in ds1307_trickle_init() local
1348 diode = false; in ds1307_trickle_init()
1351 diode = true; in ds1307_trickle_init()
1360 diode = false; in ds1307_trickle_init()
1363 return chip->do_trickle_setup(ds1307, ohms, diode); in ds1307_trickle_init()
/Linux-v5.10/Documentation/devicetree/bindings/iio/adc/
Dpalmas-gpadc.txt7 3 temp (with ext. diode, optional current source)

12