Searched refs:DIP (Results 1 – 13 of 13) sorted by relevance
| /Linux-v5.10/Documentation/driver-api/serial/ |
| D | rocket.rst | 28 The RocketPort ISA board requires I/O ports to be configured by the DIP 30 information on how to set the DIP switches. 92 card before installing and using it. This is done by setting a set of DIP 103 0x300h, 0x340h, 0x380h. This I/O address must be reflected in the DIP 111 software control. The DIP switch settings for the I/O address must be 116 Rocketport board must be set with the DIP switches corresponding to 117 the first board, the second board must be set with the DIP switches 119 the only place where the DIP switch settings should differ between the 145 DIP Switches DIP Switches 153 DIP Switches I/O Address Range
|
| /Linux-v5.10/arch/sh/boards/ |
| D | Kconfig | 215 DIP switch(S2-5). If you set the DIP switch for S2-5 = ON,
|
| /Linux-v5.10/arch/x86/kvm/ |
| D | emulate.c | 4421 #define DIP(_y, _i, _p) { .flags = (_y)|Intercept|CheckPerm, \ macro 4440 #define D2bvIP(_f, _i, _p) DIP((_f) | ByteOp, _i, _p), DIP(_f, _i, _p) 4469 DIP(SrcNone | Prot | Priv, vmrun, check_svme_pa), 4471 DIP(SrcNone | Prot | Priv, vmload, check_svme_pa), 4472 DIP(SrcNone | Prot | Priv, vmsave, check_svme_pa), 4473 DIP(SrcNone | Prot | Priv, stgi, check_svme), 4474 DIP(SrcNone | Prot | Priv, clgi, check_svme), 4475 DIP(SrcNone | Prot | Priv, skinit, check_svme), 4476 DIP(SrcNone | Prot | Priv, invlpga, check_svme), 4481 DIP(SrcNone, rdtscp, check_rdtsc), [all …]
|
| /Linux-v5.10/drivers/scsi/sym53c8xx_2/ |
| D | sym_defs.h | 172 #define DIP 0x01 /* sta: host/script interrupt */ macro
|
| D | sym_hipd.c | 153 else if (istat & DIP) { in sym_soft_reset() 1025 if (INB(np, nc_istat) & (INTF|SIP|DIP)) 2827 if (!(istat & (SIP|DIP))) 2851 if (istatc & DIP) 2862 } while (istatc & (SIP|DIP));
|
| /Linux-v5.10/arch/arm/boot/dts/ |
| D | am3517-evm.dts | 197 /* User DIP swithes [1:8] / User LEDS [1:2] */
|
| D | dra72-evm-common.dtsi | 317 /* To use NAND, DIP switch SW5 must be set like so:
|
| /Linux-v5.10/Documentation/networking/ |
| D | arcnet-hardware.rst | 1063 SW1: DIP-Switches for Station Address 1064 SW2: DIP-Switches for Memory Base and I/O Base addresses 1083 (DIP-Switch downwards means "0") 1087 The I/O base address is coded with DIP-Switches 6,7 and 8 of SW2: 1104 DIP Switches 1-5 of SW2 encode the RAM and ROM Address Range: 1208 DIP Switches: 1210 The DIP switches accessible on the accessible end of the card while 1227 There is another array of eight DIP switches at the top of the 1233 are in a weird order. This was tested by setting the DIP switches, 2323 There is a DIP-switch with 8 switches, used to set the shared memory address
|
| D | 6pack.rst | 79 is supplied with a DIP switch so you can easily change between the
|
| D | arcnet.rst | 161 default which is still set in DIP switches on the card. If you don't have the
|
| /Linux-v5.10/drivers/scsi/ |
| D | ncr53c8xx.h | 693 #define DIP 0x01 /* sta: host/script interrupt */ macro
|
| D | ncr53c8xx.c | 5772 if (INB(nc_istat) & (INTF|SIP|DIP)) { in ncr_timeout() 5915 if (!(istat & (SIP|DIP))) in ncr_exception() 5927 dstat = (istat & DIP) ? INB (nc_dstat) : 0; in ncr_exception() 7732 if (INB(nc_istat) & (INTF|SIP|DIP))
|
| /Linux-v5.10/drivers/gpio/ |
| D | Kconfig | 1055 includes reads of pushbuttons and DIP switches as well
|