/Linux-v4.19/Documentation/media/uapi/dvb/ |
D | frontend-stat-properties.rst | 64 measurement was not complete yet. 70 measurement for power (actually, 0 to 65535). 83 measurement was not complete yet. 88 measurement for Signal/Noise (actually, 0 to 65535). 103 In order to get the BER (Bit Error Rate) measurement, it should be 107 This measurement is monotonically increased, as the frontend gets more 114 measurement was not complete yet. 128 measurement was taken. 130 It should be noted that this measurement can be smaller than the total 132 manually restart the measurement, losing some data between each [all …]
|
/Linux-v4.19/net/mac80211/ |
D | spectmgmt.c | 202 skb_put(skb, 1 + sizeof(msr_report->u.action.u.measurement)); in ieee80211_send_refuse_measurement_request() 204 msr_report->u.action.u.measurement.action_code = in ieee80211_send_refuse_measurement_request() 206 msr_report->u.action.u.measurement.dialog_token = dialog_token; in ieee80211_send_refuse_measurement_request() 208 msr_report->u.action.u.measurement.element_id = WLAN_EID_MEASURE_REPORT; in ieee80211_send_refuse_measurement_request() 209 msr_report->u.action.u.measurement.length = in ieee80211_send_refuse_measurement_request() 212 memset(&msr_report->u.action.u.measurement.msr_elem, 0, in ieee80211_send_refuse_measurement_request() 214 msr_report->u.action.u.measurement.msr_elem.token = request_ie->token; in ieee80211_send_refuse_measurement_request() 215 msr_report->u.action.u.measurement.msr_elem.mode |= in ieee80211_send_refuse_measurement_request() 217 msr_report->u.action.u.measurement.msr_elem.type = request_ie->type; in ieee80211_send_refuse_measurement_request() 234 &mgmt->u.action.u.measurement.msr_elem, in ieee80211_process_measurement_req() [all …]
|
/Linux-v4.19/Documentation/hwmon/ |
D | adm9240 | 39 microprocessor-based systems, providing measurement and limit comparison 46 measurement. 55 The measurement cycle 57 The adm9240 driver will take a measurement reading no faster than once 59 measurement update rate and will receive cached data from the most 60 recent measurement. 62 ADM9240 has a very fast 320us temperature and voltage measurement cycle 63 with independent fan speed measurement cycles counting alternating rising 66 DS1780 measurement cycle is about once per second including fan speed. 68 LM81 measurement cycle is about once per 400ms including fan speed. [all …]
|
D | sht3x | 27 1. blocking (pull the I2C clock line down while performing the measurement) or 39 * 2000 0.5 Hz periodic measurement 40 * 1000 1 Hz periodic measurement 41 * 500 2 Hz periodic measurement 42 * 250 4 Hz periodic measurement 43 * 100 10 Hz periodic measurement 45 In the periodic measure mode, the sensor automatically triggers a measurement 75 for periodic measurement. If the interval is not supported
|
D | da9052 | 18 Channel 0: VDDOUT - measurement of the system voltage 19 Channel 1: ICH - internal battery charger current measurement 21 Channel 3: VBAT - measurement of the battery voltage 28 Channel 9: VBBAT - measurement of the backup battery voltage
|
D | max34440 | 61 voltage measurement is enabled for a given channel. Voltage measurement is 62 enabled if currX_crit is set to 0; current measurement is enabled if the 63 attribute is set to a positive value. Power measurement is only enabled if 64 channel 1 (3) is configured for voltage measurement, and channel 2 (4) is 65 configured for current measurement.
|
D | sht15 | 43 measurement and decrease power consumption, while losing on precision. 72 measurement may be invalid.
|
D | adm1025 | 27 monitor for microprocessor-based systems, providing measurement and limit 28 comparison of various system parameters. Five voltage measurement inputs
|
/Linux-v4.19/Documentation/misc-devices/ |
D | apds990x.txt | 17 functionality are highly connected. ALS measurement path must be running 20 ALS produces raw measurement values for two channels: Clear channel 32 selects suitable gain step. After each measurement, reliability of the results 33 is estimated and new measurement is triggered if necessary. 65 RW - measurement rate in Hz 68 RO - supported measurement rates
|
D | bh1770glc.txt | 42 so that measurement produces about the expected lux value. 63 RW - measurement rate in Hz 66 RO - supported measurement rates 109 RO - Supported proximity measurement rates in Hz
|
/Linux-v4.19/Documentation/virtual/kvm/ |
D | amd-memory-encryption.rst | 99 calculates a measurement of the memory contents. The measurement is a signature 119 The KVM_SEV_LAUNCH_MEASURE command is used to retrieve the measurement of the 122 measurement. Since the guest owner knows the initial contents of the guest at 123 boot, the measurement can be verified by comparing it to what the guest owner 133 __u64 uaddr; /* where to copy the measurement */ 134 __u32 len; /* length of measurement blob */ 137 For more details on the measurement verification flow, see SEV spec Section 6.4. 222 data after the measurement has been validated by the guest owner.
|
/Linux-v4.19/security/integrity/ima/ |
D | Kconfig | 33 bool "Enable carrying the IMA measurement list across a soft boot" 38 a TPM's quote after a soft boot, the IMA measurement list of the 41 Depending on the IMA policy, the measurement list can grow to 52 measurement list. If unsure, use the default 10. 66 Select the default IMA measurement template. 68 The original 'ima' measurement list template contains a 70 limited to 255 characters. The 'ima-ng' measurement list 94 Select the default hash algorithm used for the measurement 150 This option enables local measurement integrity appraisal. 152 attribute containing the file hash measurement. To protect
|
/Linux-v4.19/Documentation/devicetree/bindings/power/supply/ab8500/ |
D | fg.txt | 35 measurement, 'btemp' signal is used when NTC(negative temperature 44 for thermal measurement. 48 for thermal measurement.
|
/Linux-v4.19/Documentation/devicetree/bindings/sound/ |
D | cs43130.txt | 29 Boolean, define to enable headphone DC impedance measurement. 32 Boolean, define to enable headphone AC impedance measurement. 33 DC impedance must also be enabled for AC impedance measurement.
|
D | da7219.txt | 51 - dlg,mic-det-thr : Impedance threshold for mic detection measurement (Ohms) 67 - dlg,btn-avg : Number of 8-bit readings for averaged button measurement 69 - dlg,adc-1bit-rpt : Repeat count for 1-bit button measurement
|
D | nau8824.txt | 35 - nuvoton,sar-hysteresis: Button impedance measurement hysteresis. 37 - nuvoton,sar-voltage: Reference voltage for button impedance measurement.
|
D | nau8825.txt | 39 - nuvoton,sar-hysteresis: Button impedance measurement hysteresis. 41 - nuvoton,sar-voltage: Reference voltage for button impedance measurement.
|
/Linux-v4.19/Documentation/media/uapi/v4l/ |
D | dev-touch.rst | 30 A touch input may be determined by comparing the raw capacitance measurement to 31 a no-touch reference (or "baseline") measurement: 35 The reference measurement takes account of variations in the capacitance across
|
D | biblio.rst | 205 :title: IEC 61966-2-1 ed1.0 "Multimedia systems and equipment - Colour measurement and manageme… 215 …2-1-am1 ed1.0 "Amendment 1 - Multimedia systems and equipment - Colour measurement and management … 225 :title: IEC 61966-2-4 ed1.0 "Multimedia systems and equipment - Colour measurement and manageme… 245 :title: IEC 61966-2-5 "Multimedia systems and equipment - Colour measurement and management - P…
|
/Linux-v4.19/Documentation/security/ |
D | IMA-templates.rst | 26 which information should be included in the measurement list; a template 32 measurement entries. Defining a new template descriptor requires 41 mechanism) to generate a new measurement entry by using the template 48 (pointer to allocated data and data length) in the measurement entry structure. 86 To specify the template descriptor to be used to generate measurement entries,
|
/Linux-v4.19/Documentation/driver-api/iio/ |
D | intro.rst | 13 or temperature measurement. :doc:`Input <../input>` is, as its name suggests, 24 * inertial measurement units (IMUs)
|
/Linux-v4.19/drivers/staging/greybus/ |
D | interface.c | 462 u32 measurement; in voltage_now_show() local 466 &measurement); in voltage_now_show() 472 return sprintf(buf, "%u\n", measurement); in voltage_now_show() 481 u32 measurement; in current_now_show() local 485 &measurement); in current_now_show() 491 return sprintf(buf, "%u\n", measurement); in current_now_show() 500 u32 measurement; in power_now_show() local 504 &measurement); in power_now_show() 510 return sprintf(buf, "%u\n", measurement); in power_now_show()
|
/Linux-v4.19/drivers/iio/temperature/ |
D | mlx90632.c | 280 s32 ret, measurement; in mlx90632_read_all_channel() local 283 measurement = mlx90632_perform_measurement(data); in mlx90632_read_all_channel() 284 if (measurement < 0) { in mlx90632_read_all_channel() 285 ret = measurement; in mlx90632_read_all_channel() 293 ret = mlx90632_read_object_raw(data->regmap, measurement, in mlx90632_read_all_channel()
|
/Linux-v4.19/Documentation/ABI/testing/ |
D | sysfs-bus-iio-magnetometer-hmc5843 | 8 normal - Normal measurement configurations (default)
|
/Linux-v4.19/Documentation/driver-api/ |
D | s390-drivers.rst | 90 The channel-measurement facility 93 The channel-measurement facility provides a means to collect measurement
|