Home
last modified time | relevance | path

Searched refs:measure (Results 1 – 25 of 104) sorted by relevance

12345

/Linux-v4.19/Documentation/ABI/testing/
Dima_policy20 action: measure | dont_measure | appraise | dont_appraise |
77 measure func=BPRM_CHECK
78 measure func=FILE_MMAP mask=MAY_EXEC
79 measure func=FILE_CHECK mask=MAY_READ uid=0
80 measure func=MODULE_CHECK
81 measure func=FIRMWARE_CHECK
96 measure subj_user=system_u func=FILE_CHECK mask=MAY_READ
97 measure subj_role=system_r func=FILE_CHECK mask=MAY_READ
100 measure subj_user=_ func=FILE_CHECK mask=MAY_READ
102 Example of measure rules using alternate PCRs:
[all …]
/Linux-v4.19/Documentation/devicetree/bindings/sound/
Dcs43130.txt28 - cirrus,dc-measure:
31 - cirrus,ac-measure:
40 Define the frequencies at which to measure HP AC impedance.
41 Only used if "cirrus,dc-measure" is defined.
63 cirrus,dc-measure;
64 cirrus,ac-measure;
/Linux-v4.19/Documentation/media/uapi/rc/
Dlirc-set-measure-carrier-mode.rst12 LIRC_SET_MEASURE_CARRIER_MODE - enable or disable measure mode
27 enable = 1 means enable measure mode, enable = 0 means disable measure
36 Enable or disable measure mode. If enabled, from the next key
Dlirc-func.rst26 lirc-set-measure-carrier-mode
/Linux-v4.19/Documentation/media/uapi/dvb/
Dfrontend-stat-properties.rst33 the measure (dB measures) and ``uvalue`` is for unsigned values
63 - ``FE_SCALE_NOT_AVAILABLE`` - it failed to measure it, or the
82 - ``FE_SCALE_NOT_AVAILABLE`` - it failed to measure it, or the
100 This measure is taken during the same interval as
113 - ``FE_SCALE_NOT_AVAILABLE`` - it failed to measure it, or the
141 - ``FE_SCALE_NOT_AVAILABLE`` - it failed to measure it, or the
157 This measure is taken during the same interval as
170 - ``FE_SCALE_NOT_AVAILABLE`` - it failed to measure it, or the
198 - ``FE_SCALE_NOT_AVAILABLE`` - it failed to measure it, or the
219 - ``FE_SCALE_NOT_AVAILABLE`` - it failed to measure it, or the
[all …]
/Linux-v4.19/Documentation/devicetree/bindings/input/touchscreen/
Dimx6ul_tsc.txt14 - measure-delay-time: the value of measure delay time.
35 measure-delay-time = <0xfff>;
/Linux-v4.19/Documentation/hwmon/
Dltc299018 The chip's inputs can measure 4 voltages, or two inputs together (1+2 and 3+4)
19 can be combined to measure a differential voltage, which is typically used to
20 measure current through a series resistor, or a temperature with an external
Dsht3x35 The sht3x sensor supports a single shot mode as well as 5 periodic measure
45 In the periodic measure mode, the sensor automatically triggers a measurement
67 configured limits. Alarm only works in periodic measure mode
69 configured limits. Alarm only works in periodic measure mode
Dda905217 The ADC is used to measure the following inputs:
25 Channel 7: XY - TSI interface to measure the X and Y voltage of the touch
30 By using sysfs attributes we can measure the system voltage VDDOUT, the battery
Dda905517 The ADC is used to measure the following inputs:
24 By using sysfs attributes we can measure the system voltage VDDOUT,
Dadt746218 can also measure 13 voltages or 4 temperatures, or various combinations of the
41 The ADT7462 have a 10-bit ADC and can therefore measure temperatures
Dadm102660 measurements. Several inputs have integrated attenuators so they can measure
76 divisor. It can take as long as 1.5 seconds to measure all fan speeds.
/Linux-v4.19/tools/power/cpupower/bench/
Dcpufreq-bench_script.sh35 function measure() function
100 measure
/Linux-v4.19/tools/laptop/dslm/
Ddslm.c66 static void measure(int fd) in measure() function
161 measure(fd); in main()
/Linux-v4.19/arch/mips/cavium-octeon/
DKconfig71 tristate "Module to measure interrupt latency using Octeon CIU Timer"
73 This driver is a module to measure interrupt latency using the
/Linux-v4.19/drivers/iio/proximity/
DKconfig63 ranger sensor. This driver can be used to measure the distance
90 This driver can be used to measure the distance of objects.
/Linux-v4.19/Documentation/devicetree/bindings/power/supply/
Drx51-battery.txt13 * "vbat" - The ADC channel to measure the battery voltage
Dltc2941.txt3 All chips measure battery capacity.
/Linux-v4.19/Documentation/devicetree/bindings/hwmon/
Dlm87.txt21 cofigured to measure 5.0V power supply. Default is 3.3V.
/Linux-v4.19/Documentation/devicetree/bindings/
Dproperty-units.txt3 Properties which have a unit of measure are recommended to have a unit
/Linux-v4.19/drivers/ntb/test/
DKconfig24 This is a tool to measure raw NTB performance by transferring data
/Linux-v4.19/Documentation/devicetree/bindings/iio/temperature/
Dmlx90632.txt9 industrial applications. Since it can operate and measure ambient temperature
/Linux-v4.19/Documentation/devicetree/bindings/iio/adc/
Dqcom,spmi-iadc.txt4 A 16 bit ADC is used for current measurements. IADC can measure the current
/Linux-v4.19/drivers/devfreq/event/
DKconfig23 (Network on Chip) Probe counters to measure the bandwidth of AXI bus.
/Linux-v4.19/drivers/ras/
DKconfig24 Reliability is a measure of the ability of a system to function

12345