Searched full:bucks (Results 1 – 25 of 37) sorted by relevance
12
/Linux-v5.15/Documentation/devicetree/bindings/regulator/ |
D | rohm,bd71815-regulator.yaml | 56 comments below for bucks/LDOs which support this. 0 means 76 comments below for bucks/LDOs which support this. 0 means 85 comments below for bucks/LDOs which support this. 0 means 91 # Bucks 1 and 2 support giving separate voltages for operational states 94 # state changes. Omitting these properties from bucks 1 and 2 leave 98 # Bucks 3-5 and ldos 1-5 support setting the RUN state voltage here. 108 # that setting non zero voltages for bucks 1/2 will also enable voltage
|
D | rohm,bd71828-regulator.yaml | 54 bucks which support this. 0 means disabled. 62 bucks which support this. 0 means disabled. 70 bucks which support this. 0 means disabled. 78 bucks which support this. 0 means disabled.
|
D | samsung,s2mpa01.txt | 34 Note: Some bucks share the ramp rate setting i.e. same ramp value 35 will be set for a particular group of bucks so provide the same
|
D | rohm,bd71847-regulator.yaml | 62 bucks which support this. 0 means disabled. 70 bucks which support this. 0 means disabled. 78 bucks which support this. 0 means disabled.
|
D | rohm,bd71837-regulator.yaml | 63 bucks which support this. 0 means disabled. 71 bucks which support this. 0 means disabled. 79 bucks which support this. 0 means disabled.
|
D | samsung,s2mps11.txt | 43 Note: On S2MPS11 some bucks share the ramp rate setting i.e. same ramp value 44 will be set for a particular group of bucks so provide the same
|
D | max77802.txt | 47 -BUCKn : for BUCKs, where n can lie in range 1 to 10. 68 are: BUCKs 2-4 and LDOs 1-35. Also, it only takes effect if the regulator has
|
D | max8997-regulator.txt | 45 multiple bucks, changing the voltage value of one of the bucks may affect
|
D | mt6315-regulator.yaml | 14 that contains 4 BUCKs output which can combine with each other
|
D | max77686.txt | 26 -BUCKn : for BUCKs, where n can lie in range 1 to 9.
|
/Linux-v5.15/Documentation/devicetree/bindings/mfd/ |
D | da9062.txt | 11 da9062-regulator : : LDOs & BUCKs 22 da9062-regulator : : LDOs & BUCKs 53 - regulators : This node defines the settings for the LDOs and BUCKs.
|
D | da9063.txt | 7 da9063-regulator : : LDOs & BUCKs 24 - regulators : This node defines the settings for the LDOs and BUCKs.
|
/Linux-v5.15/drivers/regulator/ |
D | max77802-regulator.c | 256 /* BUCKS 1, 6 */ 270 /* BUCKs 2-4 */ 285 /* BUCKs 5, 7-10 */ 340 /* BUCKs 1, 6 */ 365 /* BUCKS 2-4 */ 412 /* BUCKs 7-10 */
|
D | Kconfig | 275 Say y here to support the BUCKs and LDOs regulators found on 289 Say y here to support the BUCKs and LDOs regulators found on 299 Say y here to support the BUCKs and LDOs regulators found on 309 Say y here to support the BUCKs and LDOs regulators found on 405 21 general purpose LDOs, 3 dedicated LDOs, and 5 BUCKs. All 1094 via I2C bus. S2MPA01 has 10 Bucks and 26 LDO outputs. 1110 via I2C bus. S5M8767A have 9 Bucks and 28 LDOs output and
|
D | da9063-regulator.c | 32 /* BUCKs */ 44 /* When two BUCKs are merged, they cannot be reused separately */ 107 /* Macros for voltage DC/DC converters (BUCKs) */ 229 * Bucks use single mode register field for normal operation 841 "Error while reading BUCKs configuration\n"); in da9063_regulator_probe()
|
D | bd718x7-regulator.c | 130 * Bucks 1 to 4 support DVS. PWM mode is used when voltage is changed. 131 * Bucks 5 to 8 and LDOs can use PFM and must be disabled when voltage 664 * BD71837 bucks 3 and 4 support defining their enable/disable state also 692 * bucks/LDOs which are controlled via register interface are changed. 694 * beginning of shut-down sequence. As bucks 6 and 7 are parent 1536 * - hence I keep the DVS disabled for non DVS bucks by default. I don't want
|
D | max77686-regulator.c | 42 * Values used for configuring LDOs and bucks. 112 /* Some BUCKs and LDOs supports Normal[ON/OFF] mode during suspend */
|
D | hi6421v530-regulator.c | 23 * @mode_mask: ECO mode bitmask of LDOs; for BUCKs, this masks sleep
|
D | lp87565-regulator.c | 117 /* Operations permitted on BUCKs */
|
D | hi6421-regulator.c | 35 * @mode_mask: ECO mode bitmask of LDOs; for BUCKs, this masks sleep 374 * more LDO or BUCKs simultaneously, or it may burn the chip. in hi6421_regulator_enable()
|
D | bd71815-regulator.c | 184 * Bucks 1 and 2 have two voltage selection registers where selected 340 * If bucks 1 & 2 are controlled by state machine - then the RUN state in bd7181x_buck12_set_voltage_sel()
|
D | mt6380-regulator.c | 80 * @vselon_reg: Register sections for hardware control mode of bucks
|
/Linux-v5.15/include/linux/mfd/ |
D | 88pm80x.h | 54 #define PM800_MAX_REGULATOR PM800_ID_RG_MAX /* 5 Bucks, 19 LDOs */ 55 #define PM800_NUM_BUCK (5) /*5 Bucks */ 56 #define PM800_NUM_LDO (19) /*19 Bucks */
|
/Linux-v5.15/Documentation/devicetree/bindings/usb/ |
D | mediatek,mt6360-tcpc.yaml | 14 regulators (BUCKs/LDOs), and TypeC Port Switch with Power Delivery controller.
|
/Linux-v5.15/drivers/mfd/ |
D | lp8788.c | 71 /* 4 bucks */
|
12