Lines Matching full:only
186 * Field only valid when for the received frame type the corresponding
190 * Field only valid when for the received frame type the corresponding
202 * field in address search failure cache-only entry should
216 * Supported only in full AP chips, not in client/soft
254 * Field only valid when AST_based_lookup_valid == 1.
264 * When set, all frames (data only ?) shall be encrypted. If
277 * Field only valid when key_type is set to wep_varied_width.
285 * Field only valid when bssid_hit is set.
290 * Field only valid when mpdu_qos_control_valid is set
376 * Field only valid when Mpdu_sequence_control_valid is set
386 * Field only valid when Mpdu_frame_control_valid is set
391 * Field only valid when Mpdu_frame_control_valid is set
396 * Field only valid when Mpdu_frame_control_valid is set.
400 * Field only valid when Mpdu_frame_control_valid is set.
401 * Retry bit from the frame control. Only valid when first_msdu is set
404 * Field only valid when Mpdu_sequence_control_valid is set.
409 * Field only valid when Frame_encryption_info_valid is set
419 * reason only needs to evaluate this bit and non of the other ones
462 * 0. The PPDU start status will only be valid when this bit
466 * Multicast / broadcast indicator. Only set when the MAC
468 * matches one of the 4 BSSID registers. Only set when
472 * Only valid when first_msdu is set. Indicates no AST matching
476 * Only valid when first_msdu is set. Indicates an unsuccessful
480 * Power management bit set in the 802.11 header. Only set
484 * Set if packet is not a non-QoS data frame. Only set when
489 * data format. Only set when first_msdu is set.
492 * Set if packet is a management packet. Only set when
496 * Set if packet is a control packet. Only set when first_msdu
500 * Set if more bit in frame control is set. Only set when
505 * control field is set. Only set when first_msdu is set.
512 * Set if the order bit in the frame control is set. Only
532 * Frame control field in header. Only valid when the field is marked valid.
535 * Duration field in header. Only valid when the field is marked valid.
538 * MAC addresses in the received frame. Only valid when corresponding
542 * QoS/HT control fields from header. Valid only when corresponding fields
569 * Multi-link receiver address1,2. Only valid when corresponding
805 * MPDU length before decapsulation. Only valid when first_msdu is
890 * Field Only valid if da_is_valid is set. Indicates the DA address
904 * Indicates the last MSDU of the A-MSDU. MPDU end status is only
956 * or the fragment number is not zero. Only set when first_msdu
1011 * The key ID octet from the IV. Only valid when first_msdu is set.
1067 * decapsulation. The latter is only valid if ipv4_proto or
1075 * L4 offset in bytes from the start of RX_HEADER (only valid
1078 * the start of the IP header after decapsulation (Only valid if
1111 * Set if only the TCP Ack bit is set in the TCP flags and if
1168 * Field only valid when pkt type is HT, VHT or HE. Values are
1183 * Field only valid when
1242 * 0. The PPDU start status will only be valid when this bit
1246 * Multicast / broadcast indicator. Only set when the MAC
1248 * matches one of the 4 BSSID registers. Only set when
1252 * Only valid when first_msdu is set. Indicates no AST matching
1256 * Only valid when first_msdu is set. Indicates an unsuccessful
1260 * Power management bit set in the 802.11 header. Only set
1264 * Set if packet is not a non-QoS data frame. Only set when
1269 * data format. Only set when first_msdu is set.
1272 * Set if packet is a management packet. Only set when
1276 * Set if packet is a control packet. Only set when first_msdu
1280 * Set if more bit in frame control is set. Only set when
1285 * control field is set. Only set when first_msdu is set.
1293 * Set if the order bit in the frame control is set. Only