Lines Matching full:12
31 sequences up to 12 independent voltage rails. The device integrates a 12-bit
35 The UCD90124 is a 12-rail PMBus/I2C addressable power-supply sequencer and
36 system-health monitor. The device integrates a 12-bit ADC for monitoring up to
44 monitor. The device integrates a 12-bit ADC for monitoring up to 16 power-supply
57 monitor. The device integrates a 12-bit ADC for monitoring up to 10 power-supply
64 system-health monitor. The device integrates a 12-bit ADC for monitoring up to
93 in[1-12]_label "vout[1-12]".
94 in[1-12]_input Measured voltage. From READ_VOUT register.
95 in[1-12]_min Minimum Voltage. From VOUT_UV_WARN_LIMIT register.
96 in[1-12]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register.
97 in[1-12]_lcrit Critical minimum Voltage. VOUT_UV_FAULT_LIMIT register.
98 in[1-12]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT
100 in[1-12]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
101 in[1-12]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
102 in[1-12]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT
104 in[1-12]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT
107 curr[1-12]_label "iout[1-12]".
108 curr[1-12]_input Measured current. From READ_IOUT register.
109 curr[1-12]_max Maximum current. From IOUT_OC_WARN_LIMIT register.
110 curr[1-12]_lcrit Critical minimum output current. From
112 curr[1-12]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT
114 curr[1-12]_max_alarm Current high alarm. From IOUT_OC_WARNING status.
115 curr[1-12]_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status.