Lines Matching +full:up +full:- +full:counter

1 What:		/sys/bus/counter/devices/counterX/countY/count
3 Contact: linux-iio@vger.kernel.org
7 What: /sys/bus/counter/devices/counterX/countY/capture
9 Contact: linux-iio@vger.kernel.org
13 What: /sys/bus/counter/devices/counterX/countY/ceiling
15 Contact: linux-iio@vger.kernel.org
18 respective counter.
20 What: /sys/bus/counter/devices/counterX/countY/floor
22 Contact: linux-iio@vger.kernel.org
25 respective counter.
27 What: /sys/bus/counter/devices/counterX/countY/count_mode
29 Contact: linux-iio@vger.kernel.org
42 to the Count Y floor value. The counter freezes at
43 count = ceiling when counting up, and at count = floor
48 non-recycle:
49 The counter is disabled whenever a counter overflow or
50 underflow takes place. The counter is re-enabled when a
51 new count value is loaded to the counter via a preset
54 modulo-n:
56 value and the Count Y ceiling value. The counter is
58 counting up, while the counter is set to the Count Y
60 counter does not freeze at the boundary points, but
63 What: /sys/bus/counter/devices/counterX/countY/count_mode_available
64 What: /sys/bus/counter/devices/counterX/countY/error_noise_available
65 What: /sys/bus/counter/devices/counterX/countY/function_available
66 What: /sys/bus/counter/devices/counterX/countY/prescaler_available
67 What: /sys/bus/counter/devices/counterX/countY/signalZ_action_available
69 Contact: linux-iio@vger.kernel.org
75 What: /sys/bus/counter/devices/counterX/countY/direction
77 Contact: linux-iio@vger.kernel.org
79 Read-only attribute that indicates the count direction of Count
82 Some counter devices are able to determine the direction of
88 What: /sys/bus/counter/devices/counterX/countY/enable
90 Contact: linux-iio@vger.kernel.org
92 Whether channel Y counter is enabled. Valid attribute values are
96 for Count Y. Suppose a counter device is used to count the total
98 to temporarily pause the counter, service the conveyor belt,
99 and then finally unpause the counter to continue where it had
102 What: /sys/bus/counter/devices/counterX/countY/error_noise
104 Contact: linux-iio@vger.kernel.org
106 Read-only attribute that indicates whether excessive noise is
107 present at the channel Y counter inputs.
109 What: /sys/bus/counter/devices/counterX/countY/function
111 Contact: linux-iio@vger.kernel.org
123 pulse-direction:
156 What: /sys/bus/counter/devices/counterX/countY/name
158 Contact: linux-iio@vger.kernel.org
160 Read-only attribute that indicates the device-specific name of
164 What: /sys/bus/counter/devices/counterX/countY/prescaler
166 Contact: linux-iio@vger.kernel.org
169 On the FlexTimer, the counter clock source passes through a
170 prescaler (i.e. a counter). This acts like a clock
173 What: /sys/bus/counter/devices/counterX/countY/preset
175 Contact: linux-iio@vger.kernel.org
177 If the counter device supports preset registers -- registers
178 used to load counter channels to a set count upon device-defined
179 preset operation trigger events -- the preset count for channel
182 What: /sys/bus/counter/devices/counterX/countY/preset_enable
184 Contact: linux-iio@vger.kernel.org
186 Whether channel Y counter preset operation is enabled. Valid
189 What: /sys/bus/counter/devices/counterX/countY/signalZ_action
191 Contact: linux-iio@vger.kernel.org
200 Pulse-Direction count function mode, this Signal is
212 What: /sys/bus/counter/devices/counterX/countY/num_overflows
214 Contact: linux-iio@vger.kernel.org
218 What: /sys/bus/counter/devices/counterX/countY/capture_component_id
219 What: /sys/bus/counter/devices/counterX/countY/ceiling_component_id
220 What: /sys/bus/counter/devices/counterX/countY/floor_component_id
221 What: /sys/bus/counter/devices/counterX/countY/count_mode_component_id
222 What: /sys/bus/counter/devices/counterX/countY/direction_component_id
223 What: /sys/bus/counter/devices/counterX/countY/enable_component_id
224 What: /sys/bus/counter/devices/counterX/countY/error_noise_component_id
225 What: /sys/bus/counter/devices/counterX/countY/prescaler_component_id
226 What: /sys/bus/counter/devices/counterX/countY/preset_component_id
227 What: /sys/bus/counter/devices/counterX/countY/preset_enable_component_id
228 What: /sys/bus/counter/devices/counterX/countY/signalZ_action_component_id
229 What: /sys/bus/counter/devices/counterX/countY/num_overflows_component_id
230 What: /sys/bus/counter/devices/counterX/signalY/cable_fault_component_id
231 What: /sys/bus/counter/devices/counterX/signalY/cable_fault_enable_component_id
232 What: /sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler_component_id
233 What: /sys/bus/counter/devices/counterX/signalY/index_polarity_component_id
234 What: /sys/bus/counter/devices/counterX/signalY/polarity_component_id
235 What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_component_id
236 What: /sys/bus/counter/devices/counterX/signalY/frequency_component_id
238 Contact: linux-iio@vger.kernel.org
240 Read-only attribute that indicates the component ID of the
243 What: /sys/bus/counter/devices/counterX/countY/spike_filter_ns
245 Contact: linux-iio@vger.kernel.org
247 If the counter device supports programmable spike filter this
252 What: /sys/bus/counter/devices/counterX/events_queue_size
254 Contact: linux-iio@vger.kernel.org
256 Size of the Counter events queue in number of struct
258 rounded-up to a power of 2.
260 What: /sys/bus/counter/devices/counterX/name
262 Contact: linux-iio@vger.kernel.org
264 Read-only attribute that indicates the device-specific name of
265 the Counter. This should match the name of the device as it
268 What: /sys/bus/counter/devices/counterX/num_counts
270 Contact: linux-iio@vger.kernel.org
272 Read-only attribute that indicates the total number of Counts
273 belonging to the Counter.
275 What: /sys/bus/counter/devices/counterX/num_signals
277 Contact: linux-iio@vger.kernel.org
279 Read-only attribute that indicates the total number of Signals
280 belonging to the Counter.
282 What: /sys/bus/counter/devices/counterX/signalY/cable_fault
284 Contact: linux-iio@vger.kernel.org
286 Read-only attribute that indicates whether a differential
292 What: /sys/bus/counter/devices/counterX/signalY/cable_fault_enable
294 Contact: linux-iio@vger.kernel.org
300 What: /sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler
302 Contact: linux-iio@vger.kernel.org
307 What: /sys/bus/counter/devices/counterX/signalY/index_polarity
309 Contact: linux-iio@vger.kernel.org
312 non-synchronous load mode.
314 What: /sys/bus/counter/devices/counterX/signalY/index_polarity_available
315 What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
317 Contact: linux-iio@vger.kernel.org
322 What: /sys/bus/counter/devices/counterX/signalY/polarity
324 Contact: linux-iio@vger.kernel.org
335 What: /sys/bus/counter/devices/counterX/signalY/name
337 Contact: linux-iio@vger.kernel.org
339 Read-only attribute that indicates the device-specific name of
343 What: /sys/bus/counter/devices/counterX/signalY/signal
345 Contact: linux-iio@vger.kernel.org
356 What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode
358 Contact: linux-iio@vger.kernel.org
360 Configure the counter associated with Signal Y for
361 non-synchronous or synchronous load mode. Synchronous load mode
362 cannot be selected in non-quadrature (Pulse-Direction) clock
365 non-synchronous:
378 What: /sys/bus/counter/devices/counterX/signalY/frequency
380 Contact: linux-iio@vger.kernel.org
382 Read-only attribute that indicates the signal Y frequency, in Hz.