Lines Matching full:counter
1 What: /sys/bus/counter/devices/counterX/countY/count
7 What: /sys/bus/counter/devices/counterX/countY/capture
13 What: /sys/bus/counter/devices/counterX/countY/ceiling
18 respective counter.
20 What: /sys/bus/counter/devices/counterX/countY/floor
25 respective counter.
27 What: /sys/bus/counter/devices/counterX/countY/count_mode
42 to the Count Y floor value. The counter freezes at
49 The counter is disabled whenever a counter overflow or
50 underflow takes place. The counter is re-enabled when a
51 new count value is loaded to the counter via a preset
56 value and the Count Y ceiling value. The counter is
58 counting up, while the counter is set to the Count Y
60 counter does not freeze at the boundary points, but
63 What: /sys/bus/counter/devices/counterX/countY/count_mode_available
64 What: /sys/bus/counter/devices/counterX/countY/error_noise_available
65 What: /sys/bus/counter/devices/counterX/countY/function_available
66 What: /sys/bus/counter/devices/counterX/countY/prescaler_available
67 What: /sys/bus/counter/devices/counterX/countY/signalZ_action_available
75 What: /sys/bus/counter/devices/counterX/countY/direction
82 Some counter devices are able to determine the direction of
88 What: /sys/bus/counter/devices/counterX/countY/enable
92 Whether channel Y counter is enabled. Valid attribute values are
96 for Count Y. Suppose a counter device is used to count the total
98 to temporarily pause the counter, service the conveyor belt,
99 and then finally unpause the counter to continue where it had
102 What: /sys/bus/counter/devices/counterX/countY/error_noise
107 present at the channel Y counter inputs.
109 What: /sys/bus/counter/devices/counterX/countY/function
156 What: /sys/bus/counter/devices/counterX/countY/name
164 What: /sys/bus/counter/devices/counterX/countY/prescaler
169 On the FlexTimer, the counter clock source passes through a
170 prescaler (i.e. a counter). This acts like a clock
173 What: /sys/bus/counter/devices/counterX/countY/preset
177 If the counter device supports preset registers -- registers
178 used to load counter channels to a set count upon device-defined
182 What: /sys/bus/counter/devices/counterX/countY/preset_enable
186 Whether channel Y counter preset operation is enabled. Valid
189 What: /sys/bus/counter/devices/counterX/countY/signalZ_action
212 What: /sys/bus/counter/devices/counterX/countY/num_overflows
218 What: /sys/bus/counter/devices/counterX/countY/capture_component_id
219 What: /sys/bus/counter/devices/counterX/countY/ceiling_component_id
220 What: /sys/bus/counter/devices/counterX/countY/floor_component_id
221 What: /sys/bus/counter/devices/counterX/countY/count_mode_component_id
222 What: /sys/bus/counter/devices/counterX/countY/direction_component_id
223 What: /sys/bus/counter/devices/counterX/countY/enable_component_id
224 What: /sys/bus/counter/devices/counterX/countY/error_noise_component_id
225 What: /sys/bus/counter/devices/counterX/countY/prescaler_component_id
226 What: /sys/bus/counter/devices/counterX/countY/preset_component_id
227 What: /sys/bus/counter/devices/counterX/countY/preset_enable_component_id
228 What: /sys/bus/counter/devices/counterX/countY/signalZ_action_component_id
229 What: /sys/bus/counter/devices/counterX/countY/num_overflows_component_id
230 What: /sys/bus/counter/devices/counterX/signalY/cable_fault_component_id
231 What: /sys/bus/counter/devices/counterX/signalY/cable_fault_enable_component_id
232 What: /sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler_component_id
233 What: /sys/bus/counter/devices/counterX/signalY/index_polarity_component_id
234 What: /sys/bus/counter/devices/counterX/signalY/polarity_component_id
235 What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_component_id
236 What: /sys/bus/counter/devices/counterX/signalY/frequency_component_id
243 What: /sys/bus/counter/devices/counterX/countY/spike_filter_ns
247 If the counter device supports programmable spike filter this
252 What: /sys/bus/counter/devices/counterX/events_queue_size
256 Size of the Counter events queue in number of struct
260 What: /sys/bus/counter/devices/counterX/name
265 the Counter. This should match the name of the device as it
268 What: /sys/bus/counter/devices/counterX/num_counts
273 belonging to the Counter.
275 What: /sys/bus/counter/devices/counterX/num_signals
280 belonging to the Counter.
282 What: /sys/bus/counter/devices/counterX/signalY/cable_fault
292 What: /sys/bus/counter/devices/counterX/signalY/cable_fault_enable
300 What: /sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler
307 What: /sys/bus/counter/devices/counterX/signalY/index_polarity
314 What: /sys/bus/counter/devices/counterX/signalY/index_polarity_available
315 What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
322 What: /sys/bus/counter/devices/counterX/signalY/polarity
335 What: /sys/bus/counter/devices/counterX/signalY/name
343 What: /sys/bus/counter/devices/counterX/signalY/signal
356 What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode
360 Configure the counter associated with Signal Y for
378 What: /sys/bus/counter/devices/counterX/signalY/frequency