Lines Matching full:count
1 What: /sys/bus/counter/devices/counterX/countY/count
5 Count data of Count Y represented as a string.
11 Historical capture of the Count Y count data.
17 Count value ceiling for Count Y. This is the upper limit for the
24 Count value floor for Count Y. This is the lower limit for the
31 Count mode for channel Y. The ceiling and floor values for
32 Count Y are used by the count mode where required. The following
33 count modes are available:
41 the Count Y ceiling value, while the lower limit is set
42 to the Count Y floor value. The counter freezes at
43 count = ceiling when counting up, and at count = floor
45 counting is resumed only when the count direction is
51 new count value is loaded to the counter via a preset
55 A count value boundary is set between the Count Y floor
56 value and the Count Y ceiling value. The counter is
57 reset to the Count Y floor value at count = ceiling when
58 counting up, while the counter is set to the Count Y
59 ceiling value at count = floor when counting down; the
71 Discrete set of available values for the respective Count Y
79 Read-only attribute that indicates the count direction of Count
80 Y. Two count directions are available: forward and backward.
86 This attribute exposes such count directions.
96 for Count Y. Suppose a counter device is used to count the total
113 Count function mode of Count Y; count function evaluation is
114 triggered by conditions specified by the Count Y signalZ_action
115 attributes. The following count functions are available:
118 Accumulated count is incremented.
121 Accumulated count is decremented.
124 Rising edges on signal A updates the respective count.
129 signal A updates the respective count; if the direction
131 updates the respective count. Quadrature encoding
136 signal B updates the respective count; if the direction
138 updates the respective count. Quadrature encoding
143 the respective count. Quadrature encoding determines the
148 the respective count. Quadrature encoding determines the
153 updates the respective count. Quadrature encoding
161 Count Y. If possible, this should match the name of the
168 Configure the prescaler value associated with Count Y.
178 used to load counter channels to a set count upon device-defined
179 preset operation trigger events -- the preset count for channel
193 Action mode of Count Y for Signal Z. This attribute indicates
194 the condition of Signal Z that triggers the count function
195 evaluation for Count Y. The following action modes are
199 Signal does not trigger the count function. In
200 Pulse-Direction count function mode, this Signal is
216 This attribute indicates the number of overflows of count Y.