Lines Matching full:from
179 supported, and determines available sensors from this information.
188 inX_input Measured voltage. From READ_VIN or READ_VOUT register.
190 From VIN_UV_WARN_LIMIT or VOUT_UV_WARN_LIMIT register.
192 From VIN_OV_WARN_LIMIT or VOUT_OV_WARN_LIMIT register.
194 From VIN_UV_FAULT_LIMIT or VOUT_UV_FAULT_LIMIT register.
196 From VIN_OV_FAULT_LIMIT or VOUT_OV_FAULT_LIMIT register.
197 inX_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
198 inX_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
200 From VOLTAGE_UV_FAULT status.
202 From VOLTAGE_OV_FAULT status.
205 currX_input Measured current. From READ_IIN or READ_IOUT register.
207 From IIN_OC_WARN_LIMIT or IOUT_OC_WARN_LIMIT register.
209 From IOUT_UC_FAULT_LIMIT register.
211 From IIN_OC_FAULT_LIMIT or IOUT_OC_FAULT_LIMIT register.
213 From IIN_OC_WARNING or IOUT_OC_WARNING status.
215 From IIN_OC_WARN_LIMIT or IOUT_OC_WARN_LIMIT status.
217 From IOUT_UC_FAULT status.
219 From IIN_OC_FAULT or IOUT_OC_FAULT status.
222 powerX_input Measured power. From READ_PIN or READ_POUT register.
223 powerX_cap Output power cap. From POUT_MAX register.
224 powerX_max Power limit. From PIN_OP_WARN_LIMIT or
227 From POUT_OP_FAULT_LIMIT register.
229 From PIN_OP_WARNING or POUT_OP_WARNING status.
231 From POUT_OP_FAULT status.
235 From READ_TEMPERATURE_X register.
236 tempX_min Mimimum temperature. From UT_WARN_LIMIT register.
237 tempX_max Maximum temperature. From OT_WARN_LIMIT register.
239 From UT_FAULT_LIMIT register.
241 From OT_FAULT_LIMIT register.