Lines Matching full:counter

1 What:		/sys/bus/counter/devices/counterX/countY/count
7 What: /sys/bus/counter/devices/counterX/countY/ceiling
12 respective counter.
14 What: /sys/bus/counter/devices/counterX/countY/floor
19 respective counter.
21 What: /sys/bus/counter/devices/counterX/countY/count_mode
36 to the Count Y floor value. The counter freezes at
43 The counter is disabled whenever a counter overflow or
44 underflow takes place. The counter is re-enabled when a
45 new count value is loaded to the counter via a preset
50 value and the Count Y ceiling value. The counter is
52 counting up, while the counter is set to the Count Y
54 counter does not freeze at the boundary points, but
57 What: /sys/bus/counter/devices/counterX/countY/count_mode_available
58 What: /sys/bus/counter/devices/counterX/countY/error_noise_available
59 What: /sys/bus/counter/devices/counterX/countY/function_available
60 What: /sys/bus/counter/devices/counterX/countY/prescaler_available
61 What: /sys/bus/counter/devices/counterX/countY/signalZ_action_available
69 What: /sys/bus/counter/devices/counterX/countY/direction
76 Some counter devices are able to determine the direction of
82 What: /sys/bus/counter/devices/counterX/countY/enable
86 Whether channel Y counter is enabled. Valid attribute values are
90 for Count Y. Suppose a counter device is used to count the total
92 to temporarily pause the counter, service the conveyor belt,
93 and then finally unpause the counter to continue where it had
96 What: /sys/bus/counter/devices/counterX/countY/error_noise
101 present at the channel Y counter inputs.
103 What: /sys/bus/counter/devices/counterX/countY/function
150 What: /sys/bus/counter/devices/counterX/countY/name
158 What: /sys/bus/counter/devices/counterX/countY/prescaler
163 On the FlexTimer, the counter clock source passes through a
164 prescaler (i.e. a counter). This acts like a clock
167 What: /sys/bus/counter/devices/counterX/countY/preset
171 If the counter device supports preset registers -- registers
172 used to load counter channels to a set count upon device-defined
176 What: /sys/bus/counter/devices/counterX/countY/preset_enable
180 Whether channel Y counter preset operation is enabled. Valid
183 What: /sys/bus/counter/devices/counterX/countY/signalZ_action
206 What: /sys/bus/counter/devices/counterX/countY/spike_filter_ns
210 If the counter device supports programmable spike filter this
215 What: /sys/bus/counter/devices/counterX/name
220 the Counter. This should match the name of the device as it
223 What: /sys/bus/counter/devices/counterX/num_counts
228 belonging to the Counter.
230 What: /sys/bus/counter/devices/counterX/num_signals
235 belonging to the Counter.
237 What: /sys/bus/counter/devices/counterX/signalY/cable_fault
247 What: /sys/bus/counter/devices/counterX/signalY/cable_fault_enable
255 What: /sys/bus/counter/devices/counterX/signalY/filter_clock_prescaler
262 What: /sys/bus/counter/devices/counterX/signalY/index_polarity
269 What: /sys/bus/counter/devices/counterX/signalY/index_polarity_available
270 What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode_available
277 What: /sys/bus/counter/devices/counterX/signalY/name
285 What: /sys/bus/counter/devices/counterX/signalY/signal
291 What: /sys/bus/counter/devices/counterX/signalY/synchronous_mode
295 Configure the counter associated with Signal Y for