Lines Matching full:count

1 What:		/sys/bus/counter/devices/counterX/countY/count
5 Count data of Count Y represented as a string.
11 Count value ceiling for Count Y. This is the upper limit for the
18 Count value floor for Count Y. This is the lower limit for the
25 Count mode for channel Y. The ceiling and floor values for
26 Count Y are used by the count mode where required. The following
27 count modes are available:
35 the Count Y ceiling value, while the lower limit is set
36 to the Count Y floor value. The counter freezes at
37 count = ceiling when counting up, and at count = floor
39 counting is resumed only when the count direction is
45 new count value is loaded to the counter via a preset
49 A count value boundary is set between the Count Y floor
50 value and the Count Y ceiling value. The counter is
51 reset to the Count Y floor value at count = ceiling when
52 counting up, while the counter is set to the Count Y
53 ceiling value at count = floor when counting down; the
65 Discrete set of available values for the respective Count Y
73 Read-only attribute that indicates the count direction of Count
74 Y. Two count directions are available: forward and backward.
80 This attribute exposes such count directions.
90 for Count Y. Suppose a counter device is used to count the total
107 Count function mode of Count Y; count function evaluation is
108 triggered by conditions specified by the Count Y signalZ_action
109 attributes. The following count functions are available:
112 Accumulated count is incremented.
115 Accumulated count is decremented.
118 Rising edges on signal A updates the respective count.
123 signal A updates the respective count; if the direction
125 updates the respective count. Quadrature encoding
130 signal B updates the respective count; if the direction
132 updates the respective count. Quadrature encoding
137 the respective count. Quadrature encoding determines the
142 the respective count. Quadrature encoding determines the
147 updates the respective count. Quadrature encoding
155 Count Y. If possible, this should match the name of the
162 Configure the prescaler value associated with Count Y.
172 used to load counter channels to a set count upon device-defined
173 preset operation trigger events -- the preset count for channel
187 Action mode of Count Y for Signal Z. This attribute indicates
188 the condition of Signal Z that triggers the count function
189 evaluation for Count Y. The following action modes are
193 Signal does not trigger the count function. In
194 Pulse-Direction count function mode, this Signal is