Lines Matching full:measurement

160  * enum iwl_tof_algo_type - Algorithym type for range measurement request
412 * @measure_type: Measurement type: 0 - two sided, 1 - One sided
414 * number of measurement iterations (min 2^0 = 1, max 2^14)
415 * @burst_period: Recommended value to be sent to the AP. Measurement
430 * use it for its ch est measurement (this flag will be set when we
461 * @IWL_INITIATOR_AP_FLAGS_ASAP: Request for ASAP measurement.
474 * @IWL_INITIATOR_AP_FLAGS_SECURED: request secured measurement
504 * @burst_period: Recommended value to be sent to the AP. Measurement
508 * the number of measurement iterations (min 2^0 = 1, max 2^14)
567 * @burst_period: Recommended value to be sent to the AP. Measurement
571 * the number of measurement iterations (min 2^0 = 1, max 2^14)
573 * @hltk: HLTK to be used for secured 11az measurement
574 * @tk: TK to be used for secured 11az measurement
618 * @burst_period: Recommended value to be sent to the AP. Measurement
622 * the number of measurement iterations (min 2^0 = 1, max 2^14)
625 * @cipher: pairwise cipher suite for secured measurement.
627 * @hltk: HLTK to be used for secured 11az measurement
628 * @tk: TK to be used for secured 11az measurement
665 * @burst_period: Recommended value to be sent to the AP. Measurement
669 * the number of measurement iterations (min 2^0 = 1, max 2^14)
672 * @cipher: pairwise cipher suite for secured measurement.
674 * @hltk: HLTK to be used for secured 11az measurement
675 * @tk: TK to be used for secured 11az measurement
711 * @IWL_MVM_TOF_RESPONSE_ASAP: report each AP measurement separately as soon as
761 * struct iwl_tof_range_req_cmd_v5 - start measurement cmd
785 * @common_calib: The common calib value to inject to this measurement calc
786 * @specific_calib: The specific calib value to inject to this measurement calc
811 * struct iwl_tof_range_req_cmd_v7 - start measurement cmd
821 * This is the session time for completing the measurement.
822 * @tsf_mac_id: report the measurement start time for each ap in terms of the
824 * @common_calib: The common calib value to inject to this measurement calc
825 * @specific_calib: The specific calib value to inject to this measurement calc
843 * struct iwl_tof_range_req_cmd_v8 - start measurement cmd
853 * This is the session time for completing the measurement.
854 * @tsf_mac_id: report the measurement start time for each ap in terms of the
856 * @common_calib: The common calib value to inject to this measurement calc
857 * @specific_calib: The specific calib value to inject to this measurement calc
875 * struct iwl_tof_range_req_cmd_v9 - start measurement cmd
885 * This is the session time for completing the measurement.
886 * @tsf_mac_id: report the measurement start time for each ap in terms of the
903 * struct iwl_tof_range_req_cmd_v11 - start measurement cmd
913 * This is the session time for completing the measurement.
914 * @tsf_mac_id: report the measurement start time for each ap in terms of the
945 * @IWL_TOF_ENTRY_SUCCESS: successful measurement.
951 * measurement was completed.
991 * @measure_status: current APs measurement status, one of
994 * @rtt: The Round Trip Time that took for the last measurement for
1011 * @common_calib: Calib val that was used in for this AP measurement
1012 * @specific_calib: val that was used in for this AP measurement
1040 * @measure_status: current APs measurement status, one of
1043 * @rtt: The Round Trip Time that took for the last measurement for
1056 * @start_tsf: measurement start time in TSF of the mac specified in the range
1063 * @common_calib: Calib val that was used in for this AP measurement
1064 * @specific_calib: val that was used in for this AP measurement
1093 * @measure_status: current APs measurement status, one of
1096 * @rtt: The Round Trip Time that took for the last measurement for
1109 * @start_tsf: measurement start time in TSF of the mac specified in the range
1116 * @common_calib: Calib val that was used in for this AP measurement
1117 * @specific_calib: val that was used in for this AP measurement
1150 * @measure_status: current APs measurement status, one of
1153 * @rtt: The Round Trip Time that took for the last measurement for
1166 * @start_tsf: measurement start time in TSF of the mac specified in the range
1173 * @common_calib: Calib val that was used in for this AP measurement
1174 * @specific_calib: val that was used in for this AP measurement
1216 * @IWL_TOF_RESPONSE_ABORTED: Measurement aborted by command.
1217 * @IWL_TOF_RESPONSE_FAILED: Measurement request command failed.
1229 * @request_status: status of current measurement session, one of