Lines Matching full:manager
2 Charger Manager
7 Charger Manager provides in-kernel battery charger management that
12 Charger Manager is a platform_driver with power-supply-class entries.
13 An instance of Charger Manager (a platform-device created with Charger-Manager)
16 the system may need multiple instances of Charger Manager.
21 Charger Manager supports the following:
43 Charger Manager provides a function "cm_suspend_again" that can be
48 that are used by Charger Manager.
60 2. Global Charger-Manager Data related with suspend_again
62 In order to setup Charger Manager with suspend-again feature
68 multiple instances of Charger Manager share the same charger_global_desc
69 and it will manage in-suspend monitoring for all instances of Charger Manager.
76 suspend for Charger Manager. The alarm interrupt (AIE) of the rtc
77 should be able to wake up the system from suspend. Charger Manager
79 alarm if it is going to go off earlier than Charger Manager so that
80 Charger Manager does not interfere with previously-defined alarms.
90 if true, Charger Manager assumes that
97 Charger Manager provides a function "extern bool cm_suspend_again(void)".
100 function to know whether Charger Manager wants to suspend again or not.
106 if the system was woken up by Charger Manager and the polling
109 4. Charger-Manager Data (struct charger_desc)
113 battery), an instance of Charger Manager is attached to it. The following
134 If both have non-zero values, Charger Manager will check the
137 Manager will try to recharge the battery by disabling and enabling
143 If specified with a non-zero value, Charger Manager assumes
149 Required polling interval in ms. Charger Manager will poll
186 5. Notify Charger-Manager of charger events: cm_notify_event()
189 Charger Manager, a charger device driver that triggers the event can call
190 cm_notify_event(psy, type, msg) to notify the corresponding Charger Manager.
192 associated with Charger-Manager. The parameter "type"