188 supported, and determines available sensors from this information.
197 inX_input Measured voltage. From READ_VIN or READ_VOUT register.
199 From VIN_UV_WARN_LIMIT or VOUT_UV_WARN_LIMIT register.
201 From VIN_OV_WARN_LIMIT or VOUT_OV_WARN_LIMIT register.
203 From VIN_UV_FAULT_LIMIT or VOUT_UV_FAULT_LIMIT register.
205 From VIN_OV_FAULT_LIMIT or VOUT_OV_FAULT_LIMIT register.
206 inX_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status.
207 inX_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status.
209 From VOLTAGE_UV_FAULT status.
211 From VOLTAGE_OV_FAULT status.
214 From MFR_VIN_MIN or MFR_VOUT_MIN register.
216 From MFR_VIN_MAX or MFR_VOUT_MAX register.
218 currX_input Measured current. From READ_IIN or READ_IOUT register.
220 From IIN_OC_WARN_LIMIT or IOUT_OC_WARN_LIMIT register.
222 From IOUT_UC_FAULT_LIMIT register.
224 From IIN_OC_FAULT_LIMIT or IOUT_OC_FAULT_LIMIT register.
226 From IIN_OC_WARNING or IOUT_OC_WARNING status.
228 From IIN_OC_WARN_LIMIT or IOUT_OC_WARN_LIMIT status.
230 From IOUT_UC_FAULT status.
232 From IIN_OC_FAULT or IOUT_OC_FAULT status.
237 From MFR_IIN_MAX or MFR_IOUT_MAX register.
239 powerX_input Measured power. From READ_PIN or READ_POUT register.
240 powerX_cap Output power cap. From POUT_MAX register.
241 powerX_max Power limit. From PIN_OP_WARN_LIMIT or
244 From POUT_OP_FAULT_LIMIT register.
246 From PIN_OP_WARNING or POUT_OP_WARNING status.
248 From POUT_OP_FAULT status.
253 From MFR_PIN_MAX or MFR_POUT_MAX register.
256 From READ_TEMPERATURE_X register.
257 tempX_min Minimum temperature. From UT_WARN_LIMIT register.
258 tempX_max Maximum temperature. From OT_WARN_LIMIT register.
260 From UT_FAULT_LIMIT register.
262 From OT_FAULT_LIMIT register.
276 From MFR_TAMBIENT_MIN register.
278 From MFR_TAMBIENT_MAX, MFR_MAX_TEMP_1, MFR_MAX_TEMP_2 or