24 Note: because of the lack of specs only the sensors part of the uGuru is
60 level we will call banks. A bank holds data for one or more sensors. The data
67 See below for all known bank addresses, numbers of sensors in that bank,
168 This bank contains 0 sensors, iow the sensor address is ignored (but must be
186 This bank contains 16 sensors, for each sensor it contains 1 byte.
187 So far the following sensors are known to be available on all motherboards:
197 This byte holds the reading from the sensor. Sensors in Bank1 can be both
198 volt and temp sensors, this is motherboard specific. The uGuru however does
202 Volt sensors use a linear scale, a reading 0 corresponds with 0 volt and a
203 reading of 255 with 3494 mV. The sensors for higher voltages however are
208 Temp sensors also use a linear scale, a reading of 0 corresponds with 0 degree
215 Those banks contain 16 sensors, for each sensor it contains 3 bytes. Each
267 Those banks contain 3 "sensors", for each sensor it contains 5 bytes.
291 Bank 0x26 Sensors Bank2 Values / Readings (R)
294 This bank contains 6 sensors (AFAIK), for each sensor it contains 1 byte.
296 So far the following sensors are known to be available on all motherboards:
305 Bank 0x27 Sensors Bank2 Settings (R) and Bank 0x28 Sensors Bank2 Settings (W)
308 Those banks contain 6 sensors (AFAIK), for each sensor it contains 2 bytes.
333 sensors part configured so that it would shutdown my system on any out of spec