Lines Matching +full:up +full:- +full:counter

1 What:		/sys/bus/counter/devices/counterX/countY/count
3 Contact: linux-iio@vger.kernel.org
7 What: /sys/bus/counter/devices/counterX/countY/ceiling
9 Contact: linux-iio@vger.kernel.org
12 respective counter.
14 What: /sys/bus/counter/devices/counterX/countY/floor
16 Contact: linux-iio@vger.kernel.org
19 respective counter.
21 What: /sys/bus/counter/devices/counterX/countY/count_mode
23 Contact: linux-iio@vger.kernel.org
36 to the Count Y floor value. The counter freezes at
37 count = ceiling when counting up, and at count = floor
42 non-recycle:
43 The counter is disabled whenever a counter overflow or
44 underflow takes place. The counter is re-enabled when a
45 new count value is loaded to the counter via a preset
48 modulo-n:
50 value and the Count Y ceiling value. The counter is
52 counting up, while the counter is set to the Count Y
54 counter does not freeze at the boundary points, but
57 What: /sys/bus/counter/devices/counterX/countY/count_mode_available
58 What: /sys/bus/counter/devices/counterX/countY/error_noise_available
59 What: /sys/bus/counter/devices/counterX/countY/function_available
60 What: /sys/bus/counter/devices/counterX/countY/signalZ_action_available
62 Contact: linux-iio@vger.kernel.org
68 What: /sys/bus/counter/devices/counterX/countY/direction
70 Contact: linux-iio@vger.kernel.org
72 Read-only attribute that indicates the count direction of Count
75 Some counter devices are able to determine the direction of
81 What: /sys/bus/counter/devices/counterX/countY/enable
83 Contact: linux-iio@vger.kernel.org
85 Whether channel Y counter is enabled. Valid attribute values are
89 for Count Y. Suppose a counter device is used to count the total
91 to temporarily pause the counter, service the conveyor belt,
92 and then finally unpause the counter to continue where it had
95 What: /sys/bus/counter/devices/counterX/countY/error_noise
97 Contact: linux-iio@vger.kernel.org
99 Read-only attribute that indicates whether excessive noise is
100 present at the channel Y counter inputs.
102 What: /sys/bus/counter/devices/counterX/countY/function
104 Contact: linux-iio@vger.kernel.org
116 pulse-direction:
149 What: /sys/bus/counter/devices/counterX/countY/name
151 Contact: linux-iio@vger.kernel.org
153 Read-only attribute that indicates the device-specific name of
157 What: /sys/bus/counter/devices/counterX/countY/preset
159 Contact: linux-iio@vger.kernel.org
161 If the counter device supports preset registers -- registers
162 used to load counter channels to a set count upon device-defined
163 preset operation trigger events -- the preset count for channel
166 What: /sys/bus/counter/devices/counterX/countY/preset_enable
168 Contact: linux-iio@vger.kernel.org
170 Whether channel Y counter preset operation is enabled. Valid
173 What: /sys/bus/counter/devices/counterX/countY/signalZ_action
175 Contact: linux-iio@vger.kernel.org
184 Pulse-Direction count function mode, this Signal is
196 What: /sys/bus/counter/devices/counterX/name
198 Contact: linux-iio@vger.kernel.org
200 Read-only attribute that indicates the device-specific name of
201 the Counter. This should match the name of the device as it
204 What: /sys/bus/counter/devices/counterX/num_counts
206 Contact: linux-iio@vger.kernel.org
208 Read-only attribute that indicates the total number of Counts
209 belonging to the Counter.
211 What: /sys/bus/counter/devices/counterX/num_signals
213 Contact: linux-iio@vger.kernel.org
215 Read-only attribute that indicates the total number of Signals
216 belonging to the Counter.
218 What: /sys/bus/counter/devices/counterX/signalY/signal
220 Contact: linux-iio@vger.kernel.org
224 What: /sys/bus/counter/devices/counterX/signalY/name
226 Contact: linux-iio@vger.kernel.org
228 Read-only attribute that indicates the device-specific name of